Skip to content Skip to navigation menu
Vickers D03 Solenoid Valve

02-145160

Vickers D03 Solenoid Valve
Item #101813869
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Crossover All Ports Open, Restricted
Port T Pressure Rating 3000 psi
Tank Port Rating 3046
Compatible Fluids Petroleum Oil
Port Restrictor Plug Code None
Manual Override Option Code None
Spool Spring Arrangement Code C
Center Position P to T, A & B Blocked
Port Restrictor Plugs None
AC/DC DC
Function Code 8
Model No. DG4V-3-8C-VM-FW-G7-61
Electrical Connector Code None
Seal Material Buna-N
Housing Code W
Coil Rating Code G
Reducer Module No
Coil Type Code F
Spool Shift Timing N/A
Function 3-Position Spring Centered
Solenoid Indicator Lights Code None
Pressure [Max] 5000 psi
Voltage & Frequency 12 VDC
Operation Solenoid Operated
Fluid Cleanliness 19/17/14 micron
Actuation Identification Solenoid A, Solenoid B
Cycle Rate [Max] N/A
Pilot/Drain None
Surge Suppressor/Damper None
Electrical Connection No Connector
Mechanical Options None
Port T Code 7
Surge Suppressor/Damper Code None
Rated Flow [Max] 20 gal/min
No. of Stages Single Stage
Pilot Valve Type N/A
Response Type Standard Response
Solenoid Energization Code V
Pressure Port Check Valve Pressure N/A
Response Time 28 to 45 ms
Solenoid Double
Mounting Subplate/Manifold Mount
Spool Code 8
Body Material Gray Iron
EN Code None
Manual Override Plain Override
Performance High Performance
Watt Rating 30 W
Solenoid Code G
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Leakage Standard Performance
NFPA Size D03
Electrical Options None
Temperature Range [Min] -4 °F
Indicator Lights No
Actuator Type Solenoid
Spool Indicator Switch Code None
Overrides No Overrides
Valve Type High-Performance
Temperature Range [Max] 158 °F
Design No. 61
Weight 5.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison