Vickers D03 Solenoid Valve

02-146425

Vickers D03 Solenoid Valve
Item #102038742
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Port T Code 6
Housing Code None
Coil Type ISO 4400
Rated Flow [Max] 20 gal/min
Seal Material Buna-N
Tank Port Rating 3046
NFPA Size D03
Pressure Port Check Valve Pressure N/A
Coil Type Code U
Valve Type High-Performance
Response Time 15 to 23 ms
Spool Shift Timing N/A
Manual Override Plain Override
Fluid Cleanliness 19/17/14 micron
Pressure [Max] 5000 psi
Pilot/Drain None
Operation Solenoid Operated
Function 2-Position Spring Offset, End to End
Spool Code 2
Solenoid Code BL
Actuator Type Solenoid
No. of Stages Single Stage
Solenoid Energization Code None
Reducer Module No
Temperature Range [Max] 158 °F
Surge Suppressor/Damper None
Crossover All Ports Blocked
Compatible Fluids Petroleum Oil
Function Code 2
Pilot Valve Type N/A
Center Position All Ports Blocked
Port T Pressure Rating 3000 psi
Leakage Standard Performance
EN Code None
Solenoid Indicator Lights Code None
Spool Spring Arrangement Code A
Surge Suppressor/Damper Code None
Indicator Lights No
Port Restrictor Plug Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Overrides No Overrides
Electrical Connector Code None
Design No. 60
Electrical Connection DIN 43650
Body Material Gray Iron
Mounting Subplate/Manifold Mount
Coil Rating Code BL
Performance High Performance
Temperature Range [Min] -4 °F
Solenoid Single
Response Type Standard Response
Spool Indicator Switch Code None
Electrical Options None
Mechanical Options None
Model No. DG4V-3-2A-M-U-BL6-60
Manual Override Option Code None
AC/DC AC
Cycle Rate [Max] N/A
Port Restrictor Plugs None
Actuation Identification Solenoid B
Weight 5.0 LB