Vickers D03 Solenoid Valve

02-148003

Vickers D03 Solenoid Valve
Item #102042493
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Solenoid Single
Indicator Lights No
Housing Code W
Temperature Range [Max] 158 °F
Function 2-Position Spring Offset, End to End
Rated Flow [Max] 20 gal/min
No. of Stages Single Stage
Electrical Options None
Spool Spring Arrangement Code A
Operation Solenoid Operated
Port Restrictor Plugs None
Electrical Connector Code None
Mounting Subplate/Manifold Mount
Reducer Module No
Surge Suppressor/Damper None
Compatible Fluids Petroleum Oil
Center Position All Ports Blocked
Performance High Performance
Coil Type Code F
Spool Indicator Switch Code None
Manual Override Option Code None
Port T Code 6
Leakage Standard Performance
AC/DC AC
Seal Material Buna-N
NFPA Size D03
Body Material Gray Iron
Port Restrictor Plug Code None
EN Code EN21
Solenoid Code B
Actuator Type Solenoid
Solenoid Indicator Lights Code None
Pressure [Max] 5000 psi
Coil Rating Code B
Mechanical Options None
Fluid Cleanliness 19/17/14 micron
Pressure Port Check Valve Pressure N/A
Port T Pressure Rating 3000 psi
Function Code 2
Spool Code 2
Spool Shift Timing N/A
Crossover All Ports Blocked
Valve Type High-Performance
Pilot Valve Type N/A
Response Time 15 to 23 ms
Pilot/Drain None
Surge Suppressor/Damper Code None
Manual Override Plain Override
Temperature Range [Min] -4 °F
Electrical Connection No Connector
Design No. 60
Tank Port Rating 3046
Solenoid Energization Code None
Overrides No Overrides
Cycle Rate [Max] N/A
Voltage & Frequency 110/120 VAC - 50/60 Hz
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Response Type Standard Response
Model No. DG4V-3-2A-M-FW-B6-60-EN21
Actuation Identification Solenoid B
Weight 5.0 LB