Vickers D03 Solenoid Valve

02-157333

Vickers D03 Solenoid Valve
Item #102039510
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
EN Code None
Tank Port Rating 3000
Spool Shift Timing N/A
Spool Spring Arrangement Code BL
Mechanical Options None
Solenoid Indicator Lights Code L
Spool Code 2
Surge Suppressor/Damper None
Center Position All Ports Blocked
Port Restrictor Plugs None
Indicator Lights Yes
Model No. DG4V-3-2BL-M-FTWL-H7-60
Electrical Connector Code T
Cycle Rate [Max] N/A
Housing Code W
Manual Override Option Code None
Port T Pressure Rating 3000 psi
Actuator Type Solenoid
Crossover All Ports Blocked
Electrical Options None
Solenoid Single
Response Type Standard Response
Solenoid Energization Code None
Pilot/Drain None
Pressure [Max] 5075 psi
Surge Suppressor/Damper Code None
Voltage & Frequency 24 VDC
Seal Material Buna-N
Port T Code 7
NFPA Size D03
Valve Type High-Performance
Electrical Connection Wired Terminal Block
Pilot Valve Type N/A
Port Restrictor Plug Code None
Operation Solenoid Operated
Coil Type Code F
Function 2-Position Spring Offset, End to Center
Spool Indicator Switch Code None
Rated Flow [Max] 21 gal/min
Design No. 60
Coil Rating Code H
Solenoid Code H
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Function Code 2
Pressure Port Check Valve Pressure N/A
Overrides No Overrides
Reducer Module N/A
AC/DC DC
Weight 5.0 LB