Vickers D03 Solenoid Valve

02-300560

Vickers D03 Solenoid Valve
Item #101850841
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

compliances

  • 0
Coil Type Code F
Spool Spring Arrangement Code C
Solenoid Code H
Design No. 61
Crossover All Ports Open, Restricted
Actuator Type Solenoid
No. of Stages Single Stage
Port Restrictor Plugs None
Pressure [Max] 5000 psi
Solenoid Indicator Lights Code L
Temperature Range [Max] 158 °F
Temperature Range [Min] -4 °F
Pressure Port Check Valve Pressure N/A
Response Type Standard Response
Function Code 8
Electrical Connection Wired Terminal Block
Solenoid Energization Code V
Reducer Module No
Tank Port Rating 3046
Body Material Gray Iron
Spool Shift Timing N/A
Spool Code 8
Overrides No Overrides
Rated Flow [Max] 20 gal/min
Manual Override Plain Override
EN Code None
Electrical Options None
Performance High Performance
Pilot Valve Type N/A
Surge Suppressor/Damper Code None
Function 3-Position, 4-Way, Spring Centered
Port Restrictor Plug Code None
Response Time 28 to 45 ms
Center Position P to T, A & B Blocked
Manual Override Option Code None
AC/DC DC
Manufacturer Part No. DG4V 3 8C V M FTWL H7 61
Model No. DG4V-3-8C-VM-FTWL-H7-61
Valve Type High-Performance
Surge Suppressor/Damper None
Spool Indicator Switch Code None
Watt Rating 30 W
Solenoid Double
Mounting Subplate/Manifold Mount
Voltage & Frequency 24 VDC
Housing Code W
Seal Material Buna-N
Fluid Cleanliness 19/17/14 micron
Actuation Identification Solenoid A, Solenoid B
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Indicator Lights Yes
Cycle Rate [Max] N/A
NFPA Size D03
Electrical Connector Code T
Leakage Standard Performance
Mechanical Options None
Port T Code 7
Coil Rating Code H
Pilot/Drain None
Operation Solenoid Operated
Rated Flow 10.6 gal/min
Port T Pressure Rating 3000 psi
Compatible Fluids Petroleum Oil
Weight 4.6 LB