Vickers D03 Solenoid Valve

02-308544

Vickers D03 Solenoid Valve
Item #102087859
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Solenoid Single
Mounting Subplate/Manifold Mount
Leakage Standard Performance
Tank Port Rating 3046
Solenoid Indicator Lights Code None
Pressure Port Check Valve Pressure N/A
Compatible Fluids Petroleum Oil
Function Code 8
EN Code None
Response Time 28 to 45 ms
Port Restrictor Plug Code None
Spool Spring Arrangement Code B
Voltage & Frequency 24 VDC
Coil Rating Code H
Indicator Lights No
Temperature Range [Min] -4 °F
Electrical Connector Code None
Crossover All Ports Open, Restricted
Center Position P to T, A & B Blocked
Solenoid Code H
Port T Pressure Rating 3000 psi
Operation Solenoid Operated
Coil Type Code F
Surge Suppressor/Damper Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Design No. 61
Housing Code W
No. of Stages Single Stage
Rated Flow [Max] 20 gal/min
Actuator Type Solenoid
Manual Override Option Code None
NFPA Size D03
Port Restrictor Plugs None
Spool Indicator Switch Code None
Spool Code 8
Surge Suppressor/Damper None
Seal Material Buna-N
Pressure [Max] 5000 psi
Port T Code 7
Solenoid Energization Code V
Temperature Range [Max] 158 °F
Spool Shift Timing N/A
Response Type Standard Response
Valve Type High-Performance
Function 2-Position Spring Offset, End To Center, Left Hand Build
Reducer Module No
Overrides No Overrides
Fluid Cleanliness 19/17/14 micron
Mechanical Options None
Electrical Connection No Connector
Model No. DG4V-3-8BL-VM-FW-H7-61
AC/DC DC
Body Material Gray Iron
Pilot Valve Type N/A
Performance High Performance
Pilot/Drain None
Cycle Rate [Max] N/A
Electrical Options None
Manual Override Plain Override
Actuation Identification Solenoid A
Watt Rating 30 W
Weight 5.0 LB