Vickers D03 Solenoid Valve

02-310516

Vickers D03 Solenoid Valve
Item #102086486
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Tank Port Rating 3046
Operation Solenoid Operated
Pilot/Drain None
Function Code 2
Surge Suppressor/Damper None
Mounting Subplate/Manifold Mount
Crossover All Ports Blocked
Valve Type High-Performance
Solenoid Code B
Manual Override Option Code None
Solenoid Single
Spool Spring Arrangement Code B
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
AC/DC AC
Reducer Module No
Rated Flow [Max] 20 gal/min
Coil Type Code F
Housing Code W
Spool Indicator Switch Code None
Fluid Cleanliness 19/17/14 micron
Electrical Connection No Connector
Indicator Lights No
Cycle Rate [Max] N/A
Overrides No Overrides
Electrical Connector Code None
Pressure Port Check Valve Pressure N/A
EN Code None
Body Material Gray Iron
Performance High Performance
Port Restrictor Plug Code None
Pressure [Max] 5000 psi
Response Time 15 to 23 ms
Response Type Standard Response
Seal Material Buna-N
No. of Stages Single Stage
Actuation Identification Solenoid A
Electrical Options None
Port Restrictor Plugs None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Compatible Fluids Petroleum Oil
Solenoid Energization Code None
Manual Override Plain Override
Temperature Range [Min] -4 °F
Leakage Standard Performance
Pilot Valve Type N/A
Actuator Type Solenoid
Function 2-Position Spring Offset, End To Center, Left Hand Build
Temperature Range [Max] 158 °F
Surge Suppressor/Damper Code None
Design No. 60
Spool Code 2
NFPA Size D03
Spool Shift Timing N/A
Model No. DG4V 3 2BL M FW B6 60
Port T Code 6
Mechanical Options None
Center Position All Ports Blocked
Solenoid Indicator Lights Code None
Port T Pressure Rating 3000 psi
Coil Rating Code B
Weight 5.0 LB