Vickers D03 Solenoid Valve

02-311422

Vickers D03 Solenoid Valve
Item #102087845
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Pilot/Drain None
Mounting Subplate/Manifold Mount
Actuation Identification Solenoid A
Spool Shift Timing N/A
Port Restrictor Plugs None
Indicator Lights Yes
Seal Material Buna-N
Manual Override Plain Override
Mechanical Options None
Port Restrictor Plug Code None
Manual Override Option Code None
Tank Port Rating 1450
Spool Code 0
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Valve Type Standard-Duty
Rated Flow [Max] 10 gal/min
Surge Suppressor/Damper None
Pressure Port Check Valve Pressure N/A
Model No. DG4V 3S 0AL M FTWL B5 60
Coil Type Code F
Operation Solenoid Operated
Electrical Connector Code T
Center Position All Ports Open
Spool Indicator Switch Code None
No. of Stages Single Stage
NFPA Size D03
Surge Suppressor/Damper Code None
Reducer Module No
Coil Rating Code B
Leakage Standard Performance
Pilot Valve Type N/A
Temperature Range [Min] -4 °F
Response Type Standard Response
Design No. 60
Function Code 0
Actuator Type Solenoid
Pressure [Max] 5000 psi
Electrical Options None
Cycle Rate [Max] N/A
EN Code None
Solenoid Energization Code None
Temperature Range [Max] 158 °F
Housing Code W
Spool Spring Arrangement Code A
Compatible Fluids Petroleum Oil
Solenoid Single
Electrical Connection Wired Terminal Block
Fluid Cleanliness 19/17/14 micron
Solenoid Indicator Lights Code L
Port T Pressure Rating 1500 psi
Overrides No Overrides
Function 2-Position Spring Offset, Left Hand Build
Performance Standard Performance
Voltage & Frequency 110/120 VAC - 50/60 Hz
Body Material Gray Iron
Solenoid Code B
Port T Code 5
Crossover All Ports Open
Response Time 18 to 32 ms
AC/DC AC
Weight 5.0 LB