Vickers D03 Solenoid Valve

02-320082

Vickers D03 Solenoid Valve
Item #102085515
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Center Position All Ports Blocked
Rated Flow [Max] 20 gal/min
Response Type Standard Response
Manual Override Option Code None
EN Code EN21
Mounting Subplate/Manifold Mount
Port Restrictor Plugs None
Fluid Cleanliness 19/17/14 micron
Leakage Standard Performance
Solenoid Code B
Port Restrictor Plug Code None
Housing Code W
Electrical Options None
Actuation Identification Solenoid A
Actuator Type Solenoid
Compatible Fluids Petroleum Oil
Solenoid Single
Pressure Port Check Valve Pressure N/A
Response Time 15 to 23 ms
Indicator Lights Yes
Cycle Rate [Max] N/A
Coil Rating Code B
Port T Code 6
Pressure [Max] 5000 psi
Function 2-Position Spring Offset, Left Hand Build
Overrides No Overrides
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
No. of Stages Single Stage
Temperature Range [Min] -4 °F
Pilot/Drain None
Surge Suppressor/Damper Code None
AC/DC AC
Tank Port Rating 3046
Performance High Performance
Voltage & Frequency 110/120 VAC - 50/60 Hz
Design No. 60
Mechanical Options None
Seal Material Buna-N
NFPA Size D03
Spool Spring Arrangement Code A
Electrical Connection No Connector
Spool Shift Timing N/A
Electrical Connector Code None
Manual Override Plain Override
Crossover All Ports Blocked
Solenoid Energization Code None
Spool Code 2
Model No. DG4V-3-2AL-M-FWL-B6-60-EN21
Temperature Range [Max] 158 °F
Spool Indicator Switch Code None
Operation Solenoid Operated
Valve Type High-Performance
Port T Pressure Rating 3000 psi
Pilot Valve Type N/A
Solenoid Indicator Lights Code L
Surge Suppressor/Damper None
Body Material Gray Iron
Function Code 2
Coil Type Code F
Reducer Module No
Weight 5.0 LB