Vickers by Danfoss02-329102

02-329102

Vickers D08 Solenoid Valve
Item #101977868
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-329102
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Port Restrictor Plugs None
Leakage Standard Performance
Mounting Subplate/Manifold Mount
Indicator Lights No
Surge Suppressor/Damper None
Tank Port Rating 5000
Gauge Port SAE-4
Actuation Identification Solenoid B
Electrical Connector Code None
Mechanical Options None
Reducer Module No
Operation Pilot Operated
Valve Type Standard-Duty
Temperature Range [Max] 230 °F
Spool Indicator Switch Code None
Pilot Valve Type Code S
Rated Flow [Max] 175 gal/min
Response Type Code None
Port Restrictor Plug Code None
Solenoid Single
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pilot/Drain External Pilot/Internal Drain
EN Code None
Surge Suppressor/Damper Code None
No. of Stages Two Stage
Spool Code 2
Performance Standard Performance
Electrical Options Code None
NFPA Size D08
Body Material Ductile Iron
Manual Override Option Code None
Pilot Pressure Code None
Response Type Standard Response
Pilot Drain Code T
Overrides Plain Override Solenoid Ends
Pressure Port Check Valve Code None
Port T Pressure Rating 5000 psi
Electrical Options None
Manual Override Plain Override
Coil Type Code F
Actuator Type Solenoid
Seal Material Buna-N
Design No. 10
Spool Control Modification Code None
Mechanical Options Code None
Solenoid Indicator Lights Code None
AC/DC AC
Temperature Range [Min] -40 °F
Spool Center Condition B Port End
Pilot Valve Type CETOP 3, Standard Performance
Pressure Port Check Valve Pressure N/A
Voltage & Frequency 110/120 VAC - 50/60 Hz
Center Position All Ports Blocked
Reducer Module Code None
Coil Rating Code B
Compatible Fluids Petroleum Oil
Fluid Cleanliness 19/17/14 micron
Crossover All Ports Blocked
Solenoid Energization Code None
Spool Spring Arrangement Code A
Electrical Connection No Connector
Function 2-Position Spring Offset
Housing Code W
Pressure [Max] 5000 psi
Model No. DG5V-8-S-2A-T-M-FW-B-10
Gauge Ports Code None
Weight 35.0 LB