Vickers D08 Solenoid Valve
Item #101977683
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329107
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Aluminum housings can be used for pressures up to 3,000 psi
  • Steel housings must be used for operating pressures above 3,000 psi
Solenoid Double
Solenoid Indicator Lights Code None
Compatible Fluids Petroleum Oil
Function 3-Position Spring Centered
Center Position All Ports Blocked
Voltage & Frequency 110/120 VAC - 50/60 Hz
EN Code None
Electrical Connection No Connector
Spool Spring Arrangement Code C
Crossover All Ports Blocked
Reducer Module No
Gauge Port SAE-4
Reducer Module Code None
Indicator Lights No
Surge Suppressor/Damper Code None
Temperature Range [Max] 230 °F
Temperature Range [Min] -40 °F
Port Restrictor Plugs None
Leakage Standard Performance
Mechanical Options Code None
Pressure Port Check Valve Pressure N/A
Pilot Valve Type CETOP 3, Standard Performance
Pilot/Drain Internal Pilot/External Drain
Rated Flow [Max] 175 gal/min
Model No. DG5V-8-S-2C-2-M-FW-B-10
Pilot Drain Code None
Solenoid Energization Code None
Operation Pilot Operated
Valve Type Standard-Duty
Pressure Port Check Valve Code None
NFPA Size D08
Manual Override Plain Override
Actuator Type Solenoid
Coil Rating Code B
Response Type Standard Response
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Port Restrictor Plug Code None
Coil Type Code F
Pilot Valve Type Code S
Spool Indicator Switch Code None
Manual Override Option Code None
No. of Stages Two Stage
Electrical Connector Code None
AC/DC AC
Mechanical Options Adjust Pilot Chokes on Both Ends
Tank Port Rating 5000
Body Material Ductile Iron
Electrical Options Code None
Pilot Pressure Code None
Spool Control Modification Code 2
Gauge Ports Code None
Spool Code 2
Overrides Plain Override Solenoid Ends
Seal Material Buna-N
Performance Standard Performance
Fluid Cleanliness 19/17/14 micron
Housing Code W
Electrical Options None
Pressure [Max] 5000 psi
Surge Suppressor/Damper None
Port T Pressure Rating 5000 psi
Actuation Identification Solenoid A, Solenoid B
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Response Type Code None
Design No. 10
Mounting Subplate/Manifold Mount
Weight 35.0 LB