- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Crossover | P Blocked, A or B to T |
| Spool Code | 6 |
| Pressure Port Check Valve Code | None |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Port T Pressure Rating | 5000 psi |
| Manual Override Option Code | None |
| Seal Material | Buna-N |
| Function | 3-Position Spring Centered |
| Gauge Port | SAE-4 |
| Reducer Module | No |
| Indicator Lights | No |
| Electrical Options | None |
| Pilot Valve Type Code | S |
| Leakage | Standard Performance |
| Coil Type Code | F |
| Pilot Pressure Code | None |
| Port Restrictor Plug Code | None |
| Spool Spring Arrangement Code | C |
| No. of Stages | Two Stage |
| NFPA Size | D08 |
| Surge Suppressor/Damper | None |
| Electrical Options Code | None |
| Solenoid Energization Code | None |
| Operation | Pilot Operated |
| Solenoid Indicator Lights Code | None |
| Reducer Module Code | None |
| Housing Code | W |
| Center Position | P Blocked, A & B to T |
| Manual Override | Plain Override |
| Electrical Connector Code | None |
| Coil Rating Code | B |
| Model No. | DG5V-8-S-6C-M-FW-B-10 |
| Pressure Port Check Valve Pressure | N/A |
| Fluid Cleanliness | 19/17/14 micron |
| Electrical Connection | No Connector |
| AC/DC | AC |
| Pressure [Max] | 5000 psi |
| Body Material | Gray Iron |
| Rated Flow [Max] | 175 gal/min |
| Surge Suppressor/Damper Code | None |
| Response Type | Standard Response |
| Pilot Drain Code | None |
| Valve Type | Standard-Duty |
| Performance | Standard Performance |
| Mechanical Options Code | None |
| Gauge Ports Code | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Design No. | 10 |
| EN Code | None |
| Spool Control Modification Code | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Spool Center Condition | A Port and Double Offset sensing switch on B Port |
| Tank Port Rating | 5000 |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Compatible Fluids | Petroleum Oil |
| Port Restrictor Plugs | None |
| Spool Indicator Switch Code | None |
| Pilot/Drain | External Pilot/Internal Drain |
| Overrides | Plain Override Solenoid Ends |
| Response Type Code | None |
| Solenoid | Double |
| Actuator Type | Solenoid |
| Mounting | Subplate/Manifold Mount |
| Mechanical Options | None |
| Weight | 35.0 LB |