- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Tank Port Rating | 5000 |
| Pressure Port Check Valve Code | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Overrides | Plain Override Solenoid Ends |
| Spool Indicator Switch Code | None |
| Spool Code | 6 |
| Seal Material | Buna-N |
| Electrical Options Code | None |
| NFPA Size | D08 |
| Coil Rating Code | B |
| Manual Override Option Code | None |
| Spool Spring Arrangement Code | C |
| Performance | Standard Performance |
| Indicator Lights | Yes |
| Pilot/Drain | External Pilot/Internal Drain |
| Solenoid Indicator Lights Code | L |
| Electrical Options | None |
| Fluid Cleanliness | 19/17/14 micron |
| Pressure [Max] | 5000 psi |
| Leakage | Standard Performance |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Pilot Pressure Code | None |
| Spool Control Modification Code | None |
| Valve Type | Standard-Duty |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Mechanical Options Code | None |
| No. of Stages | Two Stage |
| Electrical Connector Code | T |
| Mechanical Options | None |
| Gauge Port | SAE-4 |
| Reducer Module | No |
| Design No. | 10 |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Pilot Valve Type Code | S |
| Rated Flow [Max] | 175 gal/min |
| Solenoid Energization Code | None |
| Crossover | P Blocked, A or B to T |
| Reducer Module Code | None |
| Center Position | P Blocked, A & B to T |
| Port T Pressure Rating | 5000 psi |
| Pilot Drain Code | T |
| Actuation Identification | Solenoid A, Solenoid B |
| Response Type Code | None |
| Manual Override | Plain Override |
| Temperature Range [Min] | -40 °F |
| Temperature Range [Max] | 230 °F |
| AC/DC | AC |
| Mounting | Subplate/Manifold Mount |
| Gauge Ports Code | None |
| Body Material | Ductile Iron |
| Pressure Port Check Valve Pressure | N/A |
| Housing Code | W |
| Electrical Connection | Wired Terminal Block |
| Model No. | DG5V-8-S-6C-T-M-FTWL-B-10 |
| EN Code | None |
| Solenoid | Double |
| Surge Suppressor/Damper Code | None |
| Port Restrictor Plugs | None |
| Response Type | Standard Response |
| Function | 3-Position Spring Centered |
| Surge Suppressor/Damper | None |
| Actuator Type | Solenoid |
| Compatible Fluids | Petroleum Oil |
| Port Restrictor Plug Code | None |
| Operation | Pilot Operated |
| Coil Type Code | F |
| Weight | 35.0 LB |