Vickers D08 Solenoid Valve
Item #101978887
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329249
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
  • When a drive has three pulleys, at least two should be flanged
  • If the drive has more than three pulleys, every other pulley should be flanged
Pressure Port Check Valve Code None
Temperature Range [Max] 230 °F
Tank Port Rating 5000
NFPA Size D08
Pilot Valve Type Code S
Mounting Subplate/Manifold Mount
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Spool Code 33
Solenoid Double
Housing Code W
Valve Type Standard-Duty
Pilot Valve Type CETOP 3, Standard Performance
Compatible Fluids Petroleum Oil
Coil Rating Code B
Leakage Standard Performance
Reducer Module Code None
Surge Suppressor/Damper Code None
Operation Pilot Operated
Gauge Ports Code None
Mechanical Options Code None
Port Restrictor Plugs None
Electrical Options None
Actuation Identification Solenoid A, Solenoid B
Solenoid Energization Code None
Pilot/Drain Internal Pilot/Internal Drain
Temperature Range [Min] -40 °F
AC/DC AC
Crossover P Blocked, A or B to T
Pressure Port Check Valve Pressure N/A
Actuator Type Solenoid
Electrical Connection No Connector
Gauge Port SAE-4
Electrical Options Code None
Spool Control Modification Code None
Surge Suppressor/Damper None
Function 3-Position Spring Centered
Port T Pressure Rating 5000 psi
Solenoid Indicator Lights Code None
Design No. 10
Overrides Plain Override Solenoid Ends
Mechanical Options None
Body Material Ductile Iron
Response Type Standard Response
Coil Type Code F
EN Code None
Spool Indicator Switch Code None
Seal Material Buna-N
Manual Override Option Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Fluid Cleanliness 19/17/14 micron
Electrical Connector Code None
Rated Flow [Max] 175 gal/min
Pilot Drain Code T
No. of Stages Two Stage
Center Position P Blocked, A & B to T
Port Restrictor Plug Code None
Manual Override Plain Override
Reducer Module No
Response Type Code None
Model No. DG5V-8-S-33C-T-M-FW-B-10
Performance Standard Performance
Pilot Pressure Code None
Pressure [Max] 5000 psi
Indicator Lights No
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Spring Arrangement Code C
Weight 35.0 LB