- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Mechanical Options Code | None |
| Body Material | Ductile Iron |
| Reducer Module | No |
| Gauge Port | SAE-4 |
| Function | 3-Position Spring Centered |
| Coil Rating Code | B |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Tank Port Rating | 5000 |
| Reducer Module Code | None |
| Solenoid Energization Code | None |
| Solenoid | Double |
| NFPA Size | D08 |
| Performance | Standard Performance |
| Spool Code | 33 |
| Fluid Cleanliness | 19/17/14 micron |
| Design No. | 10 |
| Model No. | DG5V-8-S-33C-T-M-FW-B-10 |
| Surge Suppressor/Damper Code | None |
| Pressure [Max] | 5000 psi |
| Surge Suppressor/Damper | None |
| Valve Type | Standard-Duty |
| Temperature Range [Max] | 230 °F |
| Electrical Connection | No Connector |
| Pressure Port Check Valve Pressure | N/A |
| Operation | Pilot Operated |
| Rated Flow [Max] | 175 gal/min |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Pilot Drain Code | T |
| Spool Control Modification Code | None |
| Temperature Range [Min] | -40 °F |
| Port Restrictor Plug Code | None |
| Pilot Pressure Code | None |
| Port Restrictor Plugs | None |
| Spool Indicator Switch Code | None |
| Seal Material | Buna-N |
| Port T Pressure Rating | 5000 psi |
| Pilot/Drain | Internal Pilot/Internal Drain |
| Electrical Options Code | None |
| Response Type | Standard Response |
| EN Code | None |
| Overrides | Plain Override Solenoid Ends |
| Manual Override | Plain Override |
| Gauge Ports Code | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Crossover | P Blocked, A or B to T |
| Compatible Fluids | Petroleum Oil |
| Pilot Valve Type Code | S |
| Mounting | Subplate/Manifold Mount |
| Leakage | Standard Performance |
| Pilot Valve Type | CETOP 3, Standard Performance |
| AC/DC | AC |
| Response Type Code | None |
| Solenoid Indicator Lights Code | None |
| Manual Override Option Code | None |
| Actuation Identification | Solenoid A, Solenoid B |
| Pressure Port Check Valve Code | None |
| Actuator Type | Solenoid |
| Center Position | P Blocked, A & B to T |
| Coil Type Code | F |
| Mechanical Options | None |
| Indicator Lights | No |
| Electrical Connector Code | None |
| Housing Code | W |
| No. of Stages | Two Stage |
| Spool Spring Arrangement Code | C |
| Electrical Options | None |
| Weight | 35.0 LB |