Skip to content Skip to navigation menu
Vickers by Danfoss02-329254

02-329254

Vickers D08 Solenoid Valve
Item #101977678
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329254
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Aluminum housings can be used for pressures up to 3,000 psi
  • Steel housings must be used for operating pressures above 3,000 psi
Response Type Code None
AC/DC AC
Electrical Options Code None
Spool Code 3
Spool Spring Arrangement Code C
Reducer Module No
Design No. 10
Pilot Valve Type Code S
Mechanical Options None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Surge Suppressor/Damper Code None
Electrical Connection No Connector
Spool Indicator Switch Code None
Solenoid Double
Performance Standard Performance
Leakage Standard Performance
Pressure Port Check Valve Code None
Pressure [Max] 5000 psi
Pilot/Drain External Pilot/Internal Drain
Port T Pressure Rating 5000 psi
Overrides Plain Override Solenoid Ends
Seal Material Buna-N
Surge Suppressor/Damper None
Pilot Pressure Code None
Pilot Valve Type CETOP 3, Standard Performance
Manual Override Plain Override
Coil Rating Code B
Port Restrictor Plug Code None
Reducer Module Code None
Fluid Cleanliness 20/18/15 micron
Electrical Connector Code None
Crossover All Ports Blocked, or P & B Blocked, A to T
Coil Type Code F
Indicator Lights No
Mounting Subplate/Manifold Mount
Spool Center Condition A Port and Double Offset sensing switch on B Port
Gauge Port SAE-4
Gauge Ports Code None
Solenoid Indicator Lights Code None
Compatible Fluids Petroleum Oil
Actuation Identification Solenoid A, Solenoid B
Pressure Port Check Valve Pressure N/A
Body Material Ductile Iron
Response Type Standard Response
Tank Port Rating 5000
Mechanical Options Code None
EN Code None
Function 3-Position Spring Centered
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Temperature Range [Max] 230 °F
Rated Flow [Max] 175 gal/min
Solenoid Energization Code None
Center Position P & B Blocked, A to T
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Temperature Range [Min] -40 °F
Operation Pilot Operated
Model No. DG5V-8-S-3C-M-FW-B-10
Electrical Options None
Port Restrictor Plugs None
No. of Stages Two Stage
Spool Control Modification Code None
Manual Override Option Code None
Actuator Type Solenoid
NFPA Size D08
Pilot Drain Code None
Valve Type Standard-Duty
Housing Code W
Weight 35.0 LB