Skip to content Skip to navigation menu
Vickers by Danfoss02-330411

02-330411

Vickers D08 Solenoid Valve
Item #101974360
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers by Danfoss02-330411
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • The DG5S8 are two-stage directional valves with an integrally-mounted DG4V3S pilot valve. These valves are used to control the direction of flow in hydraulic circuits.

compliances

  • 0

caution

  • When cylinders are used with maintenance set attachments or components, the maximum system pressure must be limited to half the rated pressure, which is 5,000 psi
Electrical Connection Wired Terminal Block
Temperature Range [Max] 230 °F
Solenoid Indicator Lights Code L
Surge Suppressor/Damper None
Pilot/Drain External Pilot/Internal Drain
Leakage High Performance
NFPA Size D08
Pressure [Max] 5000 psi
Valve Type Standard-Duty
Port Restrictor Plug Code None
Housing Code W
Function 3-Position, 4-Way, Spring Centered
Spool Center Condition A Port and Double Offset sensing switch on B Port
Fluid Cleanliness 19/17/14 micron
Compatible Fluids Petroleum Oil
Spool Spring Arrangement Code C
EN Code None
Pilot Valve Type Code H
Spool Indicator Switch Code None
Electrical Options None
AC/DC AC
Pilot Drain Code T
Model No. DG5V-8-H-6C-T-M-FTWL-B-10
Overrides Plain Override Solenoid Ends
Mounting Subplate/Manifold Mount
Mechanical Options Code None
Crossover P Blocked, A or B to T
Port T Pressure Rating 5000 psi
Performance High Performance
Tank Port Rating 5000
Solenoid Double
Temperature Range [Min] -40 °F
Surge Suppressor/Damper Code None
Pilot Valve Type CETOP 3, High Performance
Coil Rating Code B
Response Type Code None
Design No. 10
Mechanical Options None
Pressure Port Check Valve Pressure N/A
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Reducer Module No
No. of Stages Two Stage
Electrical Options Code None
Gauge Port SAE-4
Indicator Lights Yes
Spool Code 6
Manual Override Plain Override
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pilot Pressure Code None
Rated Flow [Max] 175 gal/min
Response Type Standard Response
Manual Override Option Code None
Coil Type Code F
Operation Pilot Operated
Body Material Ductile Iron
Spool Control Modification Code None
Pressure Port Check Valve Code None
Gauge Ports Code None
Center Position P Blocked, A & B to T
Seal Material Buna-N
Actuator Type Solenoid
Reducer Module Code None
Electrical Connector Code T
Port Restrictor Plugs None
Actuation Identification Solenoid A, Solenoid B
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Solenoid Energization Code None
Weight 35.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison