Vickers by Danfoss02-330426

02-330426

Vickers D08 Solenoid Valve
Item #102084121
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-330426
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Check to be certain that the idler sprocket or pulley will still clear the space available between the base housing and the mounting hole
Pressure [Max] 5000 psi
Body Material Ductile Iron
Spool Indicator Switch Code None
Actuator Type Solenoid
Surge Suppressor/Damper None
Surge Suppressor/Damper Code None
Pilot Valve Type Code H
Response Type Code None
Operation Pilot Operated
Temperature Range [Min] -40 °F
Electrical Connector Code None
Performance High Performance
Mechanical Options Code None
Electrical Options Code None
Rated Flow [Max] 175 gal/min
Mechanical Options Adjust Pilot Chokes on Both Ends
Design No. 10
Indicator Lights No
Actuation Identification Solenoid A, Solenoid B
Valve Type Standard-Duty
Gauge Port SAE-4
Solenoid Indicator Lights Code None
Tank Port Rating 5000
Reducer Module Code None
Pilot Pressure Code E
Mounting Subplate/Manifold Mount
Solenoid Energization Code V
No. of Stages Two Stage
Pilot Valve Type CETOP 3, High Performance
Center Position P to T, A & B Blocked
Coil Type Code F
Port Restrictor Plug Code None
Compatible Fluids Petroleum Oil
Electrical Options None
Seal Material Buna-N
Leakage High Performance
NFPA Size D08
Function 3-Position Spring Centered
Fluid Cleanliness 19/17/14 micron
Reducer Module No
Coil Rating Code B
Pressure Port Check Valve Pressure N/A
Pilot Drain Code T
Overrides Plain Override Solenoid Ends
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Model No. DG5V-8-H-8C-2-E-T-VM-FW-B-10
Spool Code 8
Spool Spring Arrangement Code C
Gauge Ports Code None
Housing Code W
Temperature Range [Max] 230 °F
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Manual Override Plain Override
Spool Control Modification Code 2
AC/DC AC
Response Type Standard Response
EN Code None
Electrical Connection No Connector
Pilot/Drain External Pilot/Internal Drain
Port Restrictor Plugs None
Manual Override Option Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure Port Check Valve Code None
Solenoid Double
Port T Pressure Rating 5000 psi
Crossover All Ports Open, Restricted
Weight 35.0 LB