- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Housing Code | W |
| Pilot Pressure Code | None |
| Manual Override Option Code | None |
| Overrides | Plain Override Solenoid Ends |
| Electrical Options Code | None |
| Pressure [Max] | 5000 psi |
| Performance | High Performance |
| Pressure Port Check Valve Code | None |
| Electrical Connector Code | None |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Leakage | High Performance |
| AC/DC | AC |
| Valve Type | Standard-Duty |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Response Type | Standard Response |
| Spool Code | 0 |
| Model No. | DG5V-8-H-0C-M-FW-B-10 |
| Surge Suppressor/Damper Code | None |
| Spool Indicator Switch Code | None |
| Spool Control Modification Code | None |
| Center Position | All Ports Open |
| Operation | Pilot Operated |
| Fluid Cleanliness | 19/17/14 micron |
| Reducer Module Code | None |
| NFPA Size | D08 |
| Seal Material | Buna-N |
| Spool Spring Arrangement Code | C |
| Manual Override | Plain Override |
| Mechanical Options | None |
| Port Restrictor Plug Code | None |
| Rated Flow [Max] | 175 gal/min |
| Gauge Port | SAE-4 |
| Crossover | All Ports Open |
| Pilot Valve Type | CETOP 3, High Performance |
| Coil Type Code | F |
| Solenoid Energization Code | None |
| Response Type Code | None |
| Function | 3-Position Spring Centered |
| Electrical Options | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Tank Port Rating | 5000 |
| Temperature Range [Max] | 230 °F |
| Pilot Drain Code | None |
| Port T Pressure Rating | 5000 psi |
| Actuation Identification | Solenoid A, Solenoid B |
| No. of Stages | Two Stage |
| Mechanical Options Code | None |
| Electrical Connection | No Connector |
| Solenoid | Double |
| EN Code | None |
| Design No. | 10 |
| Gauge Ports Code | None |
| Coil Rating Code | B |
| Actuator Type | Solenoid |
| Pressure Port Check Valve Pressure | N/A |
| Body Material | Ductile Iron |
| Pilot Valve Type Code | H |
| Solenoid Indicator Lights Code | None |
| Surge Suppressor/Damper | None |
| Indicator Lights | No |
| Compatible Fluids | Petroleum Oil |
| Pilot/Drain | External Pilot/Internal Drain |
| Temperature Range [Min] | -40 °F |
| Mounting | Subplate/Manifold Mount |
| Reducer Module | No |
| Port Restrictor Plugs | None |
| Weight | 35.0 LB |