Vickers D08 Solenoid Valve
Item #102024733
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-330968
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Should not be selected as a sealant for chlorine or other strong oxidizing materials
Rated Flow [Max] 175 gal/min
Response Type Code None
Gauge Port SAE-4
Response Type Standard Response
No. of Stages Two Stage
Temperature Range [Min] -40 °F
Gauge Ports Code None
Spool Indicator Switch Code None
Function 2-Position Spring Offset
Actuation Identification Solenoid B
Solenoid Indicator Lights Code None
Port Restrictor Plug Code None
Reducer Module Code None
Manual Override Option Code None
Actuator Type Solenoid
NFPA Size D08
Coil Type ISO 4400 (Din 43650) Connector
Mechanical Options Code None
Temperature Range [Max] 230 °F
Solenoid Single
Pressure [Max] 5000 psi
Pressure Port Check Valve Code None
Pilot Drain Code None
Reducer Module No
Tank Port Rating 5000
Electrical Options Code None
Indicator Lights No
Mounting Subplate/Manifold Mount
Port T Pressure Rating 5000 psi
Pressure Port Check Valve Pressure N/A
Leakage Standard Performance
Surge Suppressor/Damper Code None
Fluid Cleanliness 19/17/14 micron
Mechanical Options None
Compatible Fluids Petroleum Oil
Spool Code 2
EN Code None
Pilot Valve Type Code S
Manual Override Plain Override
AC/DC AC
Housing Code None
Center Position All Ports Blocked
Body Material Ductile Iron
Design No. 10
Port Restrictor Plugs None
Operation Pilot Operated
Electrical Connection No Connector
Electrical Options None
Seal Material Buna-N
Voltage & Frequency 110/120 VAC - 50/60 Hz
Coil Type Code U
Electrical Connector Code None
Coil Rating Code B
Spool Control Modification Code None
Model No. DG5V-8-S-2A-E-M-U-B-10
Solenoid Energization Code None
Crossover All Ports Blocked
Pilot Pressure Code E
Performance Standard Performance
Spool Spring Arrangement Code A
Overrides Plain Override Solenoid Ends
Pilot Valve Type CETOP 3, Standard Performance
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Valve Type Standard-Duty
Pilot/Drain External Pilot/External Drain
Surge Suppressor/Damper None
Weight 35.0 LB