Vickers D03 Solenoid Valve

02-333163

Vickers D03 Solenoid Valve
Item #102084201
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Center Position All Ports Open
Coil Type DIN 43650
Spool Shift Timing N/A
AC/DC DC
Operation Solenoid Operated
Indicator Lights No
Function 2-Position Spring Offset, End to End
Surge Suppressor/Damper None
Valve Type High-Performance
Pressure Port Check Valve Pressure N/A
Solenoid Indicator Lights Code None
Electrical Connection DIN 43650
Spool Code 0
Solenoid Code HL
Model No. DG4V 3 0A M U HL7 60
Spool Indicator Switch Code None
Cycle Rate [Max] N/A
Response Type Standard Response
EN Code None
Solenoid Energization Code None
Crossover All Ports Open
Coil Rating Code HL
Manual Override Option Code None
Port Restrictor Plugs None
Seal Material Buna-N
Port T Pressure Rating 3000 psi
Port Restrictor Plug Code None
Electrical Options None
Overrides No Overrides
Rated Flow [Max] 21 gal/min
Coil Type Code U
Actuator Type Solenoid
Pilot Valve Type N/A
Electrical Connector Code None
Port T Code 7
Surge Suppressor/Damper Code None
Design No. 60
Mechanical Options None
Housing Code None
Reducer Module N/A
NFPA Size D03
Pressure [Max] 5075 psi
Function Code 0
Spool Spring Arrangement Code A
Tank Port Rating 3000
Solenoid Single
Voltage & Frequency 24 VDC, Low Power Coil
Pilot/Drain None
Weight 5.0 LB