Vickers by Danfoss02-337168

02-337168

Vickers D08 Solenoid Valve
Item #101975622
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-337168
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Electrical Connection No Connector
Pressure Port Check Valve Pressure N/A
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Temperature Range [Min] -40 °F
Actuation Identification Solenoid A, Solenoid B
Pilot Valve Type Code S
AC/DC AC
Design No. 10
Mounting Subplate/Manifold Mount
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Indicator Switch Code None
Port T Pressure Rating 5000 psi
Reducer Module No
Manual Override Option Code None
Compatible Fluids Petroleum Oil
Leakage Standard Performance
Solenoid Energization Code V
Electrical Options None
Response Type Code None
Center Position P to T, A & B Blocked
Surge Suppressor/Damper None
Spool Code 8
Pressure Port Check Valve Code None
Port Restrictor Plugs None
EN Code None
Pressure [Max] 5000 psi
Actuator Type Solenoid
Seal Material Buna-N
Overrides Plain Override Solenoid Ends
Solenoid Indicator Lights Code None
Electrical Connector Code None
Crossover All Ports Open, Restricted
Surge Suppressor/Damper Code None
Coil Rating Code B
NFPA Size D08
Pilot/Drain Internal Pilot/External Drain
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Mechanical Options Adjust Pilot Chokes on Both Ends
Mechanical Options Code None
Electrical Options Code None
Reducer Module Code None
Spool Control Modification Code 2
Indicator Lights No
Fluid Cleanliness 19/17/14 micron
Gauge Ports Code None
Spool Spring Arrangement Code C
Valve Type Standard-Duty
Operation Pilot Operated
Tank Port Rating 5000
Pilot Valve Type CETOP 3, Standard Performance
Model No. DG5V-8-S-8C-2-VM-FW-B-10
Pilot Drain Code None
Function 3-Position Spring Centered
Housing Code W
Body Material Ductile Iron
Port Restrictor Plug Code None
Rated Flow [Max] 175 gal/min
Response Type Standard Response
Manual Override Plain Override
Coil Type Code F
Pilot Pressure Code None
Temperature Range [Max] 230 °F
Gauge Port SAE-4
No. of Stages Two Stage
Performance Standard Performance
Solenoid Double
Weight 35.0 LB