Skip to content Skip to navigation menu
Vickers by Danfoss02-337196

02-337196

Vickers D08 Solenoid Valve
Item #101984025
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers by Danfoss02-337196
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Aluminum housings can be used for pressures up to 3,000 psi
  • Steel housings must be used for operating pressures above 3,000 psi
Mounting Subplate/Manifold Mount
Pilot/Drain External Pilot/Internal Drain
Overrides Plain Override Solenoid Ends
Spool Spring Arrangement Code N
Body Material Ductile Iron
Spool Control Modification Code None
Seal Material Buna-N
Response Type Code None
Actuator Type Solenoid
No. of Stages Two Stage
Electrical Options Code None
Crossover All Ports Blocked
Fluid Cleanliness 19/17/14 micron
Manual Override Plain Override
EN Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Spool Code 2
Electrical Options None
Pressure [Max] 5000 psi
Port Restrictor Plugs None
Gauge Port SAE-4
Rated Flow [Max] 175 gal/min
AC/DC AC
Temperature Range [Min] -40 °F
Pilot Drain Code None
Indicator Lights No
Surge Suppressor/Damper Code None
Pilot Valve Type CETOP 3, Standard Performance
Compatible Fluids Petroleum Oil
Solenoid Energization Code None
Design No. 10
Pressure Port Check Valve Pressure 5 psi
Reducer Module Code None
Housing Code W
Manual Override Option Code None
Pilot Valve Type Code S
Mechanical Options None
Port T Pressure Rating 5000 psi
Response Type Standard Response
Voltage & Frequency 110/120 VAC - 50/60 Hz
Center Position All Ports Blocked
Electrical Connector Code None
Solenoid Double
Temperature Range [Max] 230 °F
Leakage Standard Performance
Coil Rating Code B
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Gauge Ports Code None
NFPA Size D08
Valve Type Standard-Duty
Solenoid Indicator Lights Code None
Tank Port Rating 5000
Actuation Identification Solenoid A, Solenoid B
Electrical Connection No Connector
Reducer Module No
Model No. DG5V-8-S-2N-K-M-FW-B-10
Mechanical Options Code None
Port Restrictor Plug Code None
Pressure Port Check Valve Code K
Performance Standard Performance
Coil Type Code F
Operation Pilot Operated
Pilot Pressure Code None
Surge Suppressor/Damper None
Function 3-Position Detented
Spool Indicator Switch Code None
Weight 35.0 LB
We're here for you