Vickers by Danfoss02-339009

02-339009

Vickers D08 Solenoid Valve
Item #102171568
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-339009
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • OSHA requires that gas-proof goggles be worn with half facepiece respirators when used against formaldehyde
Pilot Valve Type CETOP 3, Standard Performance
Leakage Standard Performance
Design No. 10
Pressure Port Check Valve Code S
Port Restrictor Plug Code None
NFPA Size D08
Spool Control Modification Code None
No. of Stages Two Stage
Pilot Drain Code None
Overrides Plain Override Solenoid Ends
Surge Suppressor/Damper None
Solenoid Double
Port Restrictor Plugs None
Performance Standard Performance
Tank Port Rating 5000
Fluid Cleanliness 19/17/14 micron
Mechanical Options None
Gauge Ports Code None
Coil Type Code F
Spool Code 8
Pressure Port Check Valve Pressure 75 psi
Manual Override Plain Override
Solenoid Energization Code V
Spool Spring Arrangement Code C
Pressure [Max] 5000 psi
Spool Indicator Switch Code None
Pilot Pressure Code None
Actuator Type Solenoid
Temperature Range [Min] -40 °F
Response Type Standard Response
Response Type Code None
Seal Material Buna-N
Electrical Options Code None
AC/DC AC
Pilot/Drain External Pilot/Internal Drain
Solenoid Indicator Lights Code L
Reducer Module Code None
Mounting Subplate/Manifold Mount
Mechanical Options Code None
Housing Code W
Electrical Connector Code T
Voltage & Frequency 110/120 VAC - 50/60 Hz
Electrical Connection Wired Terminal Block
Crossover All Ports Open, Restricted
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Actuation Identification Solenoid A, Solenoid B
Indicator Lights Yes
Temperature Range [Max] 230 °F
Center Position P to T, A & B Blocked
Electrical Options None
Port T Pressure Rating 5000 psi
Surge Suppressor/Damper Code None
Rated Flow [Max] 175 gal/min
Model No. DG5V-8-S-8C-S-VM-FTWL-B-10
Reducer Module No
Function 3-Position Spring Centered
Compatible Fluids Petroleum Oil
Body Material Ductile Iron
EN Code None
Coil Rating Code B
Manual Override Option Code None
Valve Type Standard-Duty
Operation Pilot Operated
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Pilot Valve Type Code S
Gauge Port SAE-4
Weight 35.0 LB