Vickers by Danfoss02-342570

02-342570

Vickers D08 Solenoid Valve
Item #101908914
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-342570
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Design allows for possible axial shifting of components relative to the shaft, so utilize this device where exact positioning is not critical
Solenoid Indicator Lights Code L
Housing Code W
Operation Pilot Operated
Electrical Connector Code T
Pilot/Drain Internal Pilot/Internal Drain
Pressure Port Check Valve Code None
Solenoid Double
Mechanical Options Code None
Surge Suppressor/Damper Code None
Surge Suppressor/Damper None
NFPA Size D08
Electrical Connection Wired Terminal Block
Overrides Plain Override Solenoid Ends
Crossover P Blocked, A or B to T
Pressure [Max] 5000 psi
Coil Type Code F
EN Code None
Solenoid Energization Code None
Reducer Module N/A
Spool Indicator Switch Code None
Indicator Lights Yes
Tank Port Rating 5000
Electrical Options Code None
Manual Override Plain Override
Model No. DG5V-8-S-33C-T-M-FTWL-B-10
Port Restrictor Plugs None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Electrical Options None
Gauge Port SAE-4
Response Type Standard Response
Function 3-Position Spring Centered
Center Position P Blocked, A & B to T
Port T Pressure Rating 5000 psi
Pilot Valve Type Code S
Rated Flow [Max] 185 gal/min
Valve Type Standard-Duty
Manual Override Option Code None
Design No. 10
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port Restrictor Plug Code None
Spool Spring Arrangement Code C
Response Type Code None
Reducer Module Code None
Actuator Type Solenoid
Pilot Pressure Code None
Gauge Ports Code None
AC/DC AC
Seal Material Buna-N
Spool Code 33
Pilot Drain Code T
Coil Rating Code B
Mechanical Options None
Pressure Port Check Valve Pressure N/A
Spool Control Modification Code None
Pilot Valve Type CETOP 3, Standard Performance
Weight 35.0 LB