Vickers by Danfoss02-356231

02-356231

Vickers D08 Solenoid Valve
Item #101909201
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-356231
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Pilot Drain Code None
Response Type Code None
Port Restrictor Plugs None
Response Type Standard Response
Gauge Ports Code None
AC/DC AC
Overrides Plain Override Solenoid Ends
Spool Code 2
Operation Pilot Operated
Surge Suppressor/Damper None
Port Restrictor Plug Code None
Coil Type Code U
Actuator Type Solenoid
Coil Rating Code B
Electrical Options None
Pilot Pressure Code None
Gauge Port SAE-4
Mechanical Options Adjust Pilot Chokes on Both Ends
Pilot Valve Type CETOP 3, High Performance
Mechanical Options Code None
Port T Pressure Rating 5000 psi
Manual Override Plain Override
Function 2-Position Spring Offset
Electrical Connector Code None
Valve Type Standard-Duty
Pressure Port Check Valve Code None
Solenoid Single
Pressure Port Check Valve Pressure N/A
Spool Indicator Switch Code None
Reducer Module N/A
Model No. DG5V-8-H-2A-2-M-U-B-10
Electrical Connection No Connector
Crossover All Ports Blocked
Solenoid Energization Code None
Coil Type DIN 43650
Surge Suppressor/Damper Code None
Indicator Lights No
Housing Code None
Seal Material Buna-N
Tank Port Rating 5000
Pilot Valve Type Code H
EN Code None
Manual Override Option Code None
Solenoid Indicator Lights Code None
Spool Spring Arrangement Code A
Reducer Module Code None
Electrical Options Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure [Max] 5000 psi
NFPA Size D08
Design No. 10
Pilot/Drain External Pilot/Internal Drain
Rated Flow [Max] 185 gal/min
Spool Control Modification Code 2
Center Position All Ports Blocked
Weight 35.0 LB