Vickers by Danfoss02-356502

02-356502

Vickers D08 Solenoid Valve
Item #101908958
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-356502
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Tank Port Rating 5000
Solenoid Indicator Lights Code None
Surge Suppressor/Damper None
Electrical Connector Code None
Spool Code 0
Coil Rating Code B
Coil Type Code U
Coil Type DIN 43650
Pilot Pressure Code None
Indicator Lights No
Mechanical Options None
Reducer Module N/A
Reducer Module Code None
Spool Indicator Switch Code None
Overrides Plain Override Solenoid Ends
Housing Code None
Port T Pressure Rating 5000 psi
Model No. DG5V-8-S-0A-M-U-B-10
Crossover All Ports Open
Manual Override Plain Override
Valve Type Standard-Duty
Seal Material Buna-N
Operation Pilot Operated
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pilot/Drain External Pilot/Internal Drain
Electrical Connection No Connector
Pressure [Max] 5000 psi
Port Restrictor Plug Code None
Gauge Port SAE-4
Electrical Options Code None
Response Type Code None
Pilot Valve Type Code S
Solenoid Energization Code None
Manual Override Option Code None
Spool Spring Arrangement Code A
Rated Flow [Max] 185 gal/min
Spool Control Modification Code None
Center Position All Ports Open
EN Code None
Pressure Port Check Valve Pressure N/A
Pilot Drain Code None
Surge Suppressor/Damper Code None
Response Type Standard Response
NFPA Size D08
Electrical Options None
Port Restrictor Plugs None
AC/DC AC
Pilot Valve Type CETOP 3, Standard Performance
Solenoid Single
Actuator Type Solenoid
Design No. 10
Pressure Port Check Valve Code None
Function 2-Position Spring Offset
Gauge Ports Code None
Mechanical Options Code None
Weight 35.0 LB