Vickers by Danfoss02-357131

02-357131

Vickers D08 Solenoid Valve
Item #101907260
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-357131
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
AC/DC AC
Port Restrictor Plug Code None
Coil Rating Code B
No. of Stages Two Stage
Indicator Lights No
Spool Spring Arrangement Code C
Reducer Module Code None
Coil Type ISO 4400 (Din 43650) Connector
Fluid Cleanliness 19/17/14 micron
Solenoid Indicator Lights Code None
Temperature Range [Max] 230 °F
Port Restrictor Plugs None
NFPA Size D08
Actuator Type Solenoid
Voltage & Frequency 110/120 VAC - 50/60 Hz
Housing Code None
Operation Pilot Operated
Tank Port Rating 5000
Electrical Options Code None
Surge Suppressor/Damper Code None
Function 3-Position Spring Centered
Seal Material Buna-N
Pilot Valve Type CETOP 3, High Performance
Pilot Drain Code T
Pressure [Max] 5000 psi
Pilot Valve Type Code H
Temperature Range [Min] -40 °F
Body Material Ductile Iron
Performance High Performance
Reducer Module No
Pilot Pressure Code None
Electrical Options None
EN Code None
Mounting Subplate/Manifold Mount
Valve Type Standard-Duty
Electrical Connection No Connector
Crossover P Blocked, A or B to T
Mechanical Options Adjust Pilot Chokes on Both Ends
Leakage High Performance
Mechanical Options Code None
Rated Flow [Max] 175 gal/min
Center Position P Blocked, A & B to T
Manual Override Option Code None
Electrical Connector Code None
Model No. DG5V-8-H-6C-2-T-M-U-B-10
Spool Code 6
Actuation Identification Solenoid A, Solenoid B
Solenoid Double
Manual Override Plain Override
Pressure Port Check Valve Code None
Gauge Ports Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Design No. 10
Response Type Standard Response
Pilot/Drain Internal Pilot/Internal Drain
Spool Indicator Switch Code None
Overrides Plain Override Solenoid Ends
Coil Type Code U
Response Type Code None
Port T Pressure Rating 5000 psi
Compatible Fluids Petroleum Oil
Pressure Port Check Valve Pressure N/A
Solenoid Energization Code None
Gauge Port SAE-4
Spool Control Modification Code 2
Surge Suppressor/Damper None
Weight 35.0 LB