Vickers D08 Solenoid Valve
Item #101909440
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-362304
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Indicator Lights Yes
Solenoid Indicator Lights Code L
EN Code None
Reducer Module N/A
Actuator Type Solenoid
Coil Type Code F
Tank Port Rating 5000
Design No. 10
Port Restrictor Plugs None
Port Restrictor Plug Code None
Pilot Drain Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Surge Suppressor/Damper Code None
NFPA Size D08
Electrical Options Code None
Model No. DG5V-8-H-6C-E-M-FTWL-B-10
Manual Override Plain Override
Pilot/Drain External Pilot/Internal Drain
Housing Code W
Function 3-Position Spring Centered
Manual Override Option Code None
Seal Material Buna-N
Surge Suppressor/Damper None
Spool Indicator Switch Code None
Pilot Valve Type CETOP 3, High Performance
Response Type Code None
Crossover P Blocked, A or B to T
Coil Rating Code B
Port T Pressure Rating 5000 psi
Electrical Connector Code T
Solenoid Energization Code None
Electrical Options None
Reducer Module Code None
Response Type Standard Response
Valve Type Standard-Duty
Solenoid Double
Spool Code 6
Voltage & Frequency 110/120 VAC - 50/60 Hz
Operation Pilot Operated
Overrides Plain Override Solenoid Ends
Pressure Port Check Valve Pressure N/A
Spool Spring Arrangement Code C
Mechanical Options Code None
Pressure Port Check Valve Code None
Center Position P Blocked, A & B to T
Spool Control Modification Code None
Pilot Valve Type Code H
Pressure [Max] 5000 psi
Gauge Ports Code None
Gauge Port SAE-4
Electrical Connection Wired Terminal Block
Rated Flow [Max] 185 gal/min
Mechanical Options None
AC/DC AC
Pilot Pressure Code E
Weight 35.0 LB