Vickers by Danfoss02-362388

02-362388

Vickers D08 Solenoid Valve
Item #101908740
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers by Danfoss02-362388
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Seal Material Buna-N
Manual Override Option Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Rated Flow [Max] 185 gal/min
Spool Indicator Switch Code None
Electrical Connection No Connector
Electrical Connector Code None
Center Position All Ports Blocked
Mechanical Options Code None
Solenoid Double
Model No. DG5V-8-H-2N-2-T-M-U-B-10
Port Restrictor Plugs None
NFPA Size D08
Gauge Port SAE-4
Port Restrictor Plug Code None
Coil Type DIN 43650
Electrical Options Code None
Pilot/Drain External Pilot/Internal Drain
Operation Pilot Operated
Housing Code None
Function 3-Position Detented
Design No. 10
Pressure Port Check Valve Pressure N/A
Pressure Port Check Valve Code None
Surge Suppressor/Damper None
Spool Spring Arrangement Code N
Spool Code 2
Coil Type Code U
Gauge Ports Code None
Valve Type Standard-Duty
AC/DC AC
Electrical Options None
Actuator Type Solenoid
Pilot Pressure Code None
Solenoid Energization Code None
Surge Suppressor/Damper Code None
Reducer Module Code None
Crossover All Ports Blocked
Pilot Valve Type CETOP 3, High Performance
Spool Control Modification Code 2
Port T Pressure Rating 5000 psi
Response Type Code None
Pilot Drain Code T
Solenoid Indicator Lights Code None
Tank Port Rating 5000
Manual Override Plain Override
Response Type Standard Response
Coil Rating Code B
Pressure [Max] 5000 psi
Mechanical Options Adjust Pilot Chokes on Both Ends
EN Code None
Pilot Valve Type Code H
Reducer Module N/A
Indicator Lights No
Overrides Plain Override Solenoid Ends
Weight 35.0 LB