Vickers D08 Solenoid Valve
Item #101907824
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-390112
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Pressure Port Check Valve Pressure N/A
Indicator Lights No
Gauge Port SAE-4
Model No. DG5V-8-H-0C-2-M-U-B-10
Reducer Module N/A
Spool Indicator Switch Code None
Center Position All Ports Open
Solenoid Indicator Lights Code None
Electrical Options Code None
Overrides Plain Override Solenoid Ends
Electrical Connector Code None
NFPA Size D08
Pilot Valve Type CETOP 3, High Performance
Manual Override Plain Override
Mechanical Options Code None
Port Restrictor Plugs None
AC/DC AC
Spool Control Modification Code 2
Housing Code None
Port T Pressure Rating 5000 psi
Surge Suppressor/Damper None
Valve Type Standard-Duty
Reducer Module Code None
Spool Code 0
Function 3-Position Spring Centered
Tank Port Rating 5000
Response Type Code None
Coil Type Code U
Mechanical Options Adjust Pilot Chokes on Both Ends
Pilot/Drain External Pilot/Internal Drain
Coil Type DIN 43650
Gauge Ports Code None
Seal Material Buna-N
Solenoid Energization Code None
Coil Rating Code B
Pilot Drain Code None
Operation Pilot Operated
Electrical Connection No Connector
Rated Flow [Max] 185 gal/min
Response Type Standard Response
Pressure [Max] 5000 psi
EN Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pilot Valve Type Code H
Port Restrictor Plug Code None
Solenoid Double
Actuator Type Solenoid
Crossover All Ports Open
Pressure Port Check Valve Code None
Pilot Pressure Code None
Spool Spring Arrangement Code C
Design No. 10
Manual Override Option Code None
Surge Suppressor/Damper Code None
Electrical Options None
Weight 35.0 LB