- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Electrical Connector Code | None |
| Actuator Type | Solenoid |
| Solenoid Indicator Lights Code | None |
| Electrical Options Code | None |
| No. of Stages | Two Stage |
| Mounting | Subplate/Manifold Mount |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Housing Code | None |
| Model No. | DG5V-8-H-6C-T-M-U-B-10 |
| Pilot Valve Type Code | H |
| Fluid Cleanliness | 19/17/14 micron |
| Pilot/Drain | External Pilot/Internal Drain |
| Coil Rating Code | B |
| Coil Type | ISO 4400 (Din 43650) Connector |
| Mechanical Options | None |
| Response Type Code | None |
| Manual Override Option Code | None |
| Valve Type | Standard-Duty |
| Temperature Range [Max] | 230 °F |
| Performance | High Performance |
| Surge Suppressor/Damper Code | None |
| NFPA Size | D08 |
| Seal Material | Buna-N |
| Electrical Connection | No Connector |
| Mechanical Options Code | None |
| Gauge Ports Code | None |
| Spool Spring Arrangement Code | C |
| Design No. | 10 |
| Spool Code | 6 |
| Rated Flow [Max] | 175 gal/min |
| Pressure Port Check Valve Pressure | N/A |
| Reducer Module | No |
| Coil Type Code | U |
| Center Position | P Blocked, A & B to T |
| Body Material | Ductile Iron |
| Function | 3-Position Spring Centered |
| EN Code | None |
| Overrides | Plain Override Solenoid Ends |
| Solenoid Energization Code | None |
| Surge Suppressor/Damper | None |
| Manual Override | Plain Override |
| Solenoid | Double |
| Port Restrictor Plugs | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Actuation Identification | Solenoid A, Solenoid B |
| Pressure [Max] | 5000 psi |
| Gauge Port | SAE-4 |
| Spool Control Modification Code | None |
| Electrical Options | None |
| Pressure Port Check Valve Code | None |
| Spool Indicator Switch Code | None |
| Operation | Pilot Operated |
| Crossover | P Blocked, A or B to T |
| Response Type | Standard Response |
| Port T Pressure Rating | 5000 psi |
| AC/DC | AC |
| Temperature Range [Min] | -40 °F |
| Tank Port Rating | 5000 |
| Pilot Drain Code | T |
| Port Restrictor Plug Code | None |
| Compatible Fluids | Petroleum Oil |
| Pilot Pressure Code | None |
| Indicator Lights | No |
| Reducer Module Code | None |
| Pilot Valve Type | CETOP 3, High Performance |
| Leakage | High Performance |
| Weight | 35.0 LB |