Vickers by Danfoss02-390838

02-390838

Vickers D08 Solenoid Valve
Item #101907818
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-390838
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Center Position All Ports Open
Valve Type Standard-Duty
Model No. DG5V-8-S-0C-T-M-FW-B-10
Pressure [Max] 5000 psi
Seal Material Buna-N
Manual Override Plain Override
Housing Code W
Mechanical Options None
Surge Suppressor/Damper None
Function 3-Position Spring Centered
Response Type Code None
Spool Control Modification Code None
Actuator Type Solenoid
Solenoid Indicator Lights Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Response Type Standard Response
Rated Flow [Max] 185 gal/min
Crossover All Ports Open
Pilot Valve Type Code S
Port T Pressure Rating 5000 psi
Gauge Ports Code None
AC/DC AC
Gauge Port SAE-4
Electrical Connection No Connector
Manual Override Option Code None
Design No. 10
Mechanical Options Code None
NFPA Size D08
Coil Type Code F
Overrides Plain Override Solenoid Ends
Surge Suppressor/Damper Code None
Pressure Port Check Valve Pressure N/A
Indicator Lights No
Port Restrictor Plugs None
Electrical Options Code None
Spool Indicator Switch Code None
Tank Port Rating 5000
Port Restrictor Plug Code None
Pressure Port Check Valve Code None
Pilot Drain Code T
Solenoid Double
Operation Pilot Operated
Reducer Module Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Coil Rating Code B
Spool Code 0
Solenoid Energization Code None
Electrical Options None
Spool Spring Arrangement Code C
Reducer Module N/A
EN Code None
Pilot Valve Type CETOP 3, Standard Performance
Electrical Connector Code None
Pilot/Drain External Pilot/Internal Drain
Pilot Pressure Code None
Weight 35.0 LB