Vickers D03 Solenoid Valve

859191

Vickers D03 Solenoid Valve
Item #101965791
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Crossover All Ports Blocked
Center Position All Ports Blocked
Surge Suppressor/Damper None
Indicator Lights No
Pressure Port Check Valve Pressure N/A
Port T Code 6
Operation Solenoid Operated
Valve Type High-Performance
Solenoid Energization Code None
Cycle Rate [Max] N/A
AC/DC AC
Coil Type DIN 43650
Overrides No Overrides
Solenoid Single
Model No. DG4V 3 2AL M U C6 60
EN Code None
Mechanical Options None
Voltage & Frequency 220 VAC - 50 Hz
Actuator Type Solenoid
Solenoid Indicator Lights Code None
Electrical Connector Code None
Manual Override Option Code None
Tank Port Rating 3000
Seal Material Buna-N
Function Code 2
Reducer Module N/A
Port Restrictor Plug Code None
Coil Rating Code C
Electrical Options None
Spool Shift Timing N/A
Design No. 60
Housing Code None
Response Type Standard Response
Pressure [Max] 5075 psi
Pilot/Drain None
NFPA Size D03
Pilot Valve Type N/A
Spool Spring Arrangement Code AL
Spool Code 2
Surge Suppressor/Damper Code None
Spool Indicator Switch Code None
Rated Flow [Max] 21 gal/min
Solenoid Code C
Port Restrictor Plugs None
Function 2-Position Spring Offset, End to End
Port T Pressure Rating 3000 psi
Electrical Connection DIN 43650
Coil Type Code U
Weight 5.0 LB