Vickers D03 Solenoid Valve

870252

Vickers D03 Solenoid Valve
Item #101923274
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
Mounting Subplate/Manifold Mount
Function Code 0
Solenoid Code D
Tank Port Rating 3046
Model No. DG4V 3 0C M U D6 60
Spool Indicator Switch Code None
Cycle Rate [Max] N/A
Seal Material Buna-N
Rated Flow [Max] 20 gal/min
Design No. 60
Actuator Type Solenoid
Crossover All Ports Open
Pressure [Max] 5000 psi
Spool Shift Timing N/A
Spool Spring Arrangement Code C
Solenoid Double
Overrides No Overrides
Surge Suppressor/Damper None
Temperature Range [Max] 158 °F
Mechanical Options None
Operation Solenoid Operated
Spool Code 0
Center Position All Ports Open
Port T Pressure Rating 3000 psi
Response Type Standard Response
Pressure Port Check Valve Pressure N/A
Performance High Performance
Surge Suppressor/Damper Code None
Actuation Identification Solenoid A, Solenoid B
AC/DC AC
Port Restrictor Plug Code None
Body Material Gray Iron
Electrical Connector Code None
Response Time 15 to 23 ms
Pilot Valve Type N/A
Leakage Standard Performance
Coil Rating Code D
Manual Override Plain Override
Port Restrictor Plugs None
Housing Code None
Manual Override Option Code None
Indicator Lights No
Solenoid Indicator Lights Code None
Fluid Cleanliness 19/17/14 micron
Electrical Options None
EN Code None
Coil Type ISO 4400
Coil Type Code U
Reducer Module No
No. of Stages Single Stage
Function 3-Position Spring Centered
Pilot/Drain None
Port T Code 6
NFPA Size D03
Valve Type High-Performance
Electrical Connection DIN 43650
Voltage & Frequency 220/240 VAC - 50/60 Hz
Compatible Fluids Petroleum Oil
Solenoid Energization Code None
Temperature Range [Min] -4 °F
Weight 5.0 LB