Vickers D03 Solenoid Valve

871223

Vickers D03 Solenoid Valve
Item #101922602
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Pilot Valve Type N/A
Mechanical Options None
Port T Pressure Rating 3000 psi
Electrical Connection No Connector
Actuation Identification Solenoid A
No. of Stages Single Stage
Port Restrictor Plugs None
Tank Port Rating 3046
Spool Spring Arrangement Code B
Solenoid Energization Code None
Pilot/Drain None
Fluid Cleanliness 19/17/14 micron
Model No. DG4V 3 0BL M FW B6 60
Spool Code 0
NFPA Size D03
Electrical Options None
Leakage Standard Performance
Manual Override Plain Override
Coil Type Code F
Pressure [Max] 5000 psi
EN Code None
Rated Flow [Max] 20 gal/min
Center Position All Ports Open
Overrides No Overrides
Body Material Gray Iron
Crossover All Ports Open
Valve Type High-Performance
Pressure Port Check Valve Pressure N/A
Performance High Performance
Seal Material Buna-N
Indicator Lights No
Coil Rating Code B
Operation Solenoid Operated
Solenoid Code B
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Temperature Range [Min] -4 °F
Solenoid Indicator Lights Code None
Design No. 60
Port Restrictor Plug Code None
Temperature Range [Max] 158 °F
Solenoid Single
Reducer Module No
Port T Code 6
Function Code 0
Voltage & Frequency 110/120 VAC - 50/60 Hz
Response Time 15 to 23 ms
Electrical Connector Code None
Spool Shift Timing N/A
AC/DC AC
Compatible Fluids Petroleum Oil
Actuator Type Solenoid
Response Type Standard Response
Surge Suppressor/Damper Code None
Function 2-Position Spring Offset, End To Center, Left Hand Build
Housing Code W
Manual Override Option Code None
Surge Suppressor/Damper None
Cycle Rate [Max] N/A
Mounting Subplate/Manifold Mount
Spool Indicator Switch Code None
Weight 5.0 LB