Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Mult. Sym.
L1
Mounting Style
F-1
Poles
4
Hz
60 Hz
HP [Min]
50
Full Load Amps
57
Frame Size
326T
Service Factor
1.15
Brake Feature
No
Rotation
R
Voltage
460
Voltage Rating
460
Frame Material
Cast Iron
VoltCode
G
Efficiency Group
Standard Efficient
Model
XEX
Design
B
Product Line
RG
C Face Kit
12-1105
Frame
326T
Enclosure
Totally Enclosed
Motor Shaft Length
5 1/4 in
Full Load Pf
87
Washdown Duty
No
RPM
1800 rpm
Phase
Three Phase
Motor Application
Severe Duty
Type
1266M
Full Load Efficiency
94.5 %
Drive End Bearing
6312
C Dimension
30 1/4 in
Full Load rpm
1775 rpm
Motor Shaft Size
2 1/8 in
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
RefPicture
ECP03
Epact Nominal Full Load Efficiency
93 %
Open End Bearing
6311
Mounting
Foot Mounted
Useable at 208V
No
Weight
643.0 LB
EAN or UPC
781568107553
NEMA Premium
My Applied Catalog