Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Type
3956M
Epact Nominal Full Load Efficiency
88.5 %
Voltage
230/460
Useable at 208V
Yes
Washdown Duty
No
Motor Application
General Purpose
Phase
Three Phase
C Face Kit
39-1400
Poles
6
Drive End Bearing
6309
BALD Family Names
Premium Efficient, Nema Premium™
VoltCode
E1
Enclosure Designation
OPSB - Open Slotted Band
Mounting
Rigid Base
Efficiency Group
Standard Efficient
Rotation
R
Brake Feature
No
Voltage Rating
460, 230
Open End Bearing
6208
Frame
254T
Full Load Amps
10.7
Full Load rpm
1180 rpm
Mounting Style
F-1
RPM
1200 rpm
Full Load Efficiency
91.7 %
Motor Shaft Length
4 in
Frame Size
Shaft Input, Not a C-Face
Enclosure
OPSB
Service Factor
1.15
Product Line
RG
RefPicture
EMDP
Frame Material
Steel
Design
B
C Dimension
21.69 in
Full Load Pf
71
Motor Shaft Size
1 5/8 in
Mult. Sym.
L1
Hz
60 Hz
Substitute Motor
M2506T
Weight
239.0 LB
EAN or UPC
781568104712
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back