Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Useable at 208V
Yes
Hz
60 Hz
Enclosure Designation
OPSB - Open Slotted Band
Voltage
230/460
Phase
Three Phase
Poles
6
Rotation
R
Product Line
RG
Design
B
Full Load rpm
1180 rpm
Efficiency Group
Standard Efficient
Mounting
Rigid Base
Substitute Motor
M2506T
Frame Material
Steel
Drive End Bearing
6309
Frame
254T
Voltage Rating
460, 230
Frame Size
Shaft Input, Not a C-Face
Type
3956M
RefPicture
EMDP
BALD Family Names
Premium Efficient, Nema Premium™
Open End Bearing
6208
Motor Shaft Length
4 in
Motor Shaft Size
1 5/8 in
Mounting Style
F-1
VoltCode
E1
Washdown Duty
No
RPM
1200 rpm
Service Factor
1.15
C Face Kit
39-1400
Brake Feature
No
Mult. Sym.
L1
Full Load Amps
10.7
Epact Nominal Full Load Efficiency
88.5 %
Full Load Pf
71
Enclosure
OPSB
C Dimension
21.69 in
Full Load Efficiency
91.7 %
Motor Application
General Purpose
Weight
239.0 LB
EAN or UPC
781568104712
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back