Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Phase
Three Phase
C Face Kit
10-1305
Brake Feature
No
Frame Size
286T
Mounting
Foot Mounted
Motor Application
Severe Duty
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Poles
4
Full Load Pf
83
VoltCode
G
RefPicture
ECP03
Useable at 208V
No
Motor Shaft Size
1 7/8 in
Washdown Duty
No
RPM
1800 rpm
Voltage Rating
460
Rotation
R
Efficiency Group
Standard Efficient
Full Load rpm
1770 rpm
Type
1060M
C Dimension
27.57 in
Voltage
460
Frame Material
Cast Iron
Substitute Motor
CP4104T-4
Product Line
RG
Enclosure
Totally Enclosed
Motor Shaft Length
4 5/8 in
Full Load Efficiency
94.1 %
Mounting Style
F-1
Frame
286T
Open End Bearing
6309
Hz
60 Hz
Full Load Amps
36
Service Factor
1.15
Design
B
HP [Min]
30
Model
XEX
Drive End Bearing
6311
Mult. Sym.
L1
Epact Nominal Full Load Efficiency
92.4 %
Weight
470.0 LB
EAN or UPC
781568107447
NEMA Premium
My Applied Catalog