Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Motor Shaft Size
1 7/8 in
VoltCode
G
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Voltage
460
Mult. Sym.
L1
C Face Kit
10-1305
Substitute Motor
CP4104T-4
Useable at 208V
No
Service Factor
1.15
Full Load Efficiency
94.1 %
Poles
4
Frame Size
286T
HP [Min]
30
Frame
286T
Efficiency Group
Standard Efficient
Open End Bearing
6309
Enclosure
Totally Enclosed
C Dimension
27.57 in
Drive End Bearing
6311
Voltage Rating
460
Mounting Style
F-1
Mounting
Foot Mounted
Motor Shaft Length
4 5/8 in
RPM
1800 rpm
Washdown Duty
No
Phase
Three Phase
Epact Nominal Full Load Efficiency
92.4 %
Rotation
R
Product Line
RG
Type
1060M
Brake Feature
No
Full Load Amps
36
Frame Material
Cast Iron
Design
B
Motor Application
Severe Duty
Full Load rpm
1770 rpm
Model
XEX
Hz
60 Hz
Full Load Pf
83
RefPicture
ECP03
Weight
470.0 LB
EAN or UPC
781568107447
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back