Vickers by Danfoss02-325884

02-325884

Vickers D08 Solenoid Valve
Item #101978263
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-325884
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Surge Suppressor/Damper Code None
Valve Type Standard-Duty
Overrides Plain Override Solenoid Ends
Manual Override Option Code None
Pilot/Drain External Pilot/Internal Drain
No. of Stages Two Stage
Pressure Port Check Valve Code S
Mechanical Options Code None
NFPA Size D08
Spool Code 0
Leakage Standard Performance
Model No. DG5V-8-S-0C-S-M-FW-B-10
Temperature Range [Min] -40 °F
Seal Material Buna-N
Pilot Pressure Code None
Actuation Identification Solenoid A, Solenoid B
Design No. 10
Spool Indicator Switch Code None
Function 3-Position Spring Centered
Gauge Ports Code None
Solenoid Double
AC/DC AC
Spool Spring Arrangement Code C
Pilot Valve Type CETOP 3, Standard Performance
Body Material Ductile Iron
Solenoid Energization Code None
Compatible Fluids Petroleum Oil
Performance Standard Performance
Tank Port Rating 5000
Pressure [Max] 5000 psi
Reducer Module No
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Indicator Lights No
Response Type Standard Response
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Housing Code W
Pilot Valve Type Code S
Electrical Options None
Pressure Port Check Valve Pressure 75 psi
Temperature Range [Max] 230 °F
Mounting Subplate/Manifold Mount
Center Position All Ports Open
Rated Flow [Max] 175 gal/min
Gauge Port SAE-4
Fluid Cleanliness 20/18/15 micron
Response Type Code None
Spool Center Condition A Port and Double Offset sensing switch on B Port
EN Code None
Reducer Module Code None
Coil Type Code F
Spool Control Modification Code None
Operation Pilot Operated
Actuator Type Solenoid
Pilot Drain Code None
Port T Pressure Rating 5000 psi
Electrical Connection No Connector
Port Restrictor Plug Code None
Electrical Options Code None
Coil Rating Code B
Electrical Connector Code None
Manual Override Plain Override
Voltage & Frequency 110/120 VAC - 50/60 Hz
Mechanical Options None
Port Restrictor Plugs None
Crossover All Ports Open
Surge Suppressor/Damper None
Solenoid Indicator Lights Code None
Weight 35.0 LB