Vickers by Danfoss02-329115

02-329115

Vickers D08 Solenoid Valve
Item #101978890
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329115
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
  • When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
  • When a drive has three pulleys, at least two should be flanged
  • If the drive has more than three pulleys, every other pulley should be flanged
Port Restrictor Plugs None
Solenoid Energization Code None
Actuator Type Solenoid
Temperature Range [Max] 230 °F
Center Position All Ports Blocked
Spool Indicator Switch Code None
NFPA Size D08
Pressure Port Check Valve Code K
Indicator Lights No
Actuation Identification Solenoid A, Solenoid B
Temperature Range [Min] -40 °F
Crossover All Ports Blocked
Surge Suppressor/Damper None
Spool Spring Arrangement Code C
Function 3-Position Spring Centered
Port Restrictor Plug Code None
Electrical Connection No Connector
Leakage Standard Performance
Seal Material Buna-N
Reducer Module Code None
Mounting Subplate/Manifold Mount
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pressure [Max] 5000 psi
Voltage & Frequency 110/120 VAC - 50/60 Hz
Surge Suppressor/Damper Code None
Pilot/Drain Internal Pilot/External Drain
Tank Port Rating 5000
Pilot Drain Code None
Rated Flow [Max] 175 gal/min
Coil Rating Code B
AC/DC AC
Gauge Port SAE-4
Electrical Connector Code None
Valve Type Standard-Duty
Model No. DG5V-8-S-2C-K-M-FW-B-10
Mechanical Options Code None
Spool Code 2
Coil Type Code F
Response Type Code None
Response Type Standard Response
Electrical Options Code None
Fluid Cleanliness 19/17/14 micron
Solenoid Double
Body Material Ductile Iron
Port T Pressure Rating 5000 psi
Operation Pilot Operated
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Electrical Options None
Overrides Plain Override Solenoid Ends
Reducer Module No
Housing Code W
Pressure Port Check Valve Pressure 5 psi
Spool Control Modification Code None
Solenoid Indicator Lights Code None
No. of Stages Two Stage
Mechanical Options None
Compatible Fluids Petroleum Oil
Performance Standard Performance
Pilot Pressure Code None
Pilot Valve Type CETOP 3, Standard Performance
Manual Override Plain Override
Manual Override Option Code None
EN Code None
Gauge Ports Code None
Pilot Valve Type Code S
Design No. 10
Weight 35.0 LB