- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Coil Type Code | F |
| Surge Suppressor/Damper Code | None |
| Port Restrictor Plug Code | None |
| Overrides | Plain Override Solenoid Ends |
| Indicator Lights | No |
| Crossover | All Ports Blocked |
| Gauge Ports Code | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Performance | Standard Performance |
| Manual Override | Plain Override |
| Pilot Valve Type Code | S |
| Leakage | Standard Performance |
| Pressure [Max] | 5000 psi |
| Body Material | Ductile Iron |
| Mounting | Subplate/Manifold Mount |
| Gauge Port | SAE-4 |
| Mechanical Options Code | None |
| Electrical Options | None |
| Pilot Pressure Code | None |
| NFPA Size | D08 |
| Solenoid | Double |
| Function | 3-Position Spring Centered |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Response Type Code | None |
| Model No. | DG5V-8-S-2C-K-M-FW-B-10 |
| Response Type | Standard Response |
| Tank Port Rating | 5000 |
| Spool Control Modification Code | None |
| Reducer Module | No |
| Temperature Range [Min] | -40 °F |
| Spool Indicator Switch Code | None |
| Actuation Identification | Solenoid A, Solenoid B |
| Electrical Options Code | None |
| Actuator Type | Solenoid |
| AC/DC | AC |
| Electrical Connection | No Connector |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| No. of Stages | Two Stage |
| Spool Code | 2 |
| Fluid Cleanliness | 19/17/14 micron |
| Port Restrictor Plugs | None |
| Mechanical Options | None |
| Pressure Port Check Valve Pressure | 5 psi |
| Design No. | 10 |
| Center Position | All Ports Blocked |
| Compatible Fluids | Petroleum Oil |
| Pilot/Drain | Internal Pilot/External Drain |
| Pressure Port Check Valve Code | K |
| Temperature Range [Max] | 230 °F |
| EN Code | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Electrical Connector Code | None |
| Housing Code | W |
| Spool Spring Arrangement Code | C |
| Operation | Pilot Operated |
| Solenoid Indicator Lights Code | None |
| Surge Suppressor/Damper | None |
| Port T Pressure Rating | 5000 psi |
| Rated Flow [Max] | 175 gal/min |
| Manual Override Option Code | None |
| Reducer Module Code | None |
| Seal Material | Buna-N |
| Coil Rating Code | B |
| Solenoid Energization Code | None |
| Valve Type | Standard-Duty |
| Pilot Drain Code | None |
| Weight | 35.0 LB |