- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Tank Port Rating | 5000 |
| Temperature Range [Max] | 230 °F |
| Spool Code | 2 |
| Port T Pressure Rating | 5000 psi |
| Model No. | DG5V-8-S-2C-K-M-FW-B-10 |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Mechanical Options Code | None |
| Spool Spring Arrangement Code | C |
| EN Code | None |
| Electrical Options Code | None |
| Electrical Connection | No Connector |
| Surge Suppressor/Damper | None |
| Reducer Module | No |
| Solenoid Energization Code | None |
| Crossover | All Ports Blocked |
| Surge Suppressor/Damper Code | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Overrides | Plain Override Solenoid Ends |
| No. of Stages | Two Stage |
| Operation | Pilot Operated |
| Rated Flow [Max] | 175 gal/min |
| Electrical Connector Code | None |
| Pressure [Max] | 5000 psi |
| Actuation Identification | Solenoid A, Solenoid B |
| Gauge Port | SAE-4 |
| Coil Rating Code | B |
| Spool Control Modification Code | None |
| Electrical Options | None |
| Pressure Port Check Valve Pressure | 5 psi |
| Spool Indicator Switch Code | None |
| Center Position | All Ports Blocked |
| Indicator Lights | No |
| Manual Override | Plain Override |
| Coil Type Code | F |
| Valve Type | Standard-Duty |
| Design No. | 10 |
| Compatible Fluids | Petroleum Oil |
| AC/DC | AC |
| Actuator Type | Solenoid |
| Housing Code | W |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Body Material | Ductile Iron |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Solenoid | Double |
| Mechanical Options | None |
| Mounting | Subplate/Manifold Mount |
| Reducer Module Code | None |
| NFPA Size | D08 |
| Pilot Pressure Code | None |
| Port Restrictor Plug Code | None |
| Port Restrictor Plugs | None |
| Response Type | Standard Response |
| Leakage | Standard Performance |
| Temperature Range [Min] | -40 °F |
| Fluid Cleanliness | 19/17/14 micron |
| Gauge Ports Code | None |
| Performance | Standard Performance |
| Seal Material | Buna-N |
| Solenoid Indicator Lights Code | None |
| Pressure Port Check Valve Code | K |
| Manual Override Option Code | None |
| Response Type Code | None |
| Function | 3-Position Spring Centered |
| Pilot Drain Code | None |
| Pilot/Drain | Internal Pilot/External Drain |
| Pilot Valve Type Code | S |
| Weight | 35.0 LB |