- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Manual Override | Plain Override |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Pressure [Max] | 5000 psi |
| Port T Pressure Rating | 5000 psi |
| Pilot/Drain | Internal Pilot/External Drain |
| Pilot Drain Code | None |
| Mechanical Options Code | None |
| Crossover | All Ports Blocked |
| Leakage | Standard Performance |
| Port Restrictor Plug Code | None |
| Rated Flow [Max] | 175 gal/min |
| Pilot Valve Type Code | S |
| Coil Rating Code | B |
| Solenoid | Double |
| Fluid Cleanliness | 19/17/14 micron |
| Manual Override Option Code | None |
| Valve Type | Standard-Duty |
| Compatible Fluids | Petroleum Oil |
| Gauge Port | SAE-4 |
| Design No. | 10 |
| Electrical Options | None |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Seal Material | Buna-N |
| Temperature Range [Min] | -40 °F |
| Surge Suppressor/Damper Code | None |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Electrical Connection | No Connector |
| NFPA Size | D08 |
| EN Code | None |
| Pressure Port Check Valve Code | K |
| Tank Port Rating | 5000 |
| Indicator Lights | No |
| Coil Type Code | F |
| Solenoid Indicator Lights Code | None |
| Response Type | Standard Response |
| Actuation Identification | Solenoid A, Solenoid B |
| Pilot Pressure Code | None |
| Performance | Standard Performance |
| Electrical Connector Code | None |
| Mounting | Subplate/Manifold Mount |
| Spool Code | 2 |
| Reducer Module Code | None |
| Function | 3-Position Spring Centered |
| Response Type Code | None |
| Actuator Type | Solenoid |
| Spool Spring Arrangement Code | C |
| Housing Code | W |
| Port Restrictor Plugs | None |
| No. of Stages | Two Stage |
| Gauge Ports Code | None |
| Overrides | Plain Override Solenoid Ends |
| AC/DC | AC |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Mechanical Options | None |
| Spool Control Modification Code | None |
| Reducer Module | No |
| Model No. | DG5V-8-S-2C-K-M-FW-B-10 |
| Surge Suppressor/Damper | None |
| Operation | Pilot Operated |
| Temperature Range [Max] | 230 °F |
| Electrical Options Code | None |
| Pressure Port Check Valve Pressure | 5 psi |
| Spool Indicator Switch Code | None |
| Solenoid Energization Code | None |
| Body Material | Ductile Iron |
| Center Position | All Ports Blocked |
| Weight | 35.0 LB |