Vickers by Danfoss02-329180

02-329180

Vickers D08 Solenoid Valve
Item #102084135
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329180
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Port T Pressure Rating 5000 psi
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Temperature Range [Min] -40 °F
AC/DC AC
Model No. DG5V-8-S-6C-T-M-FW-B-10
Solenoid Double
Solenoid Energization Code None
Spool Spring Arrangement Code C
Coil Type Code F
Pressure Port Check Valve Pressure N/A
Pilot Drain Code T
Reducer Module Code None
Gauge Ports Code None
Spool Control Modification Code None
Fluid Cleanliness 19/17/14 micron
Port Restrictor Plug Code None
Operation Pilot Operated
Surge Suppressor/Damper None
Mounting Subplate/Manifold Mount
Housing Code W
Electrical Options Code None
Leakage Standard Performance
NFPA Size D08
Solenoid Indicator Lights Code None
Pilot Valve Type CETOP 3, Standard Performance
Spool Code 6
Function 3-Position Spring Centered
Performance Standard Performance
Valve Type Standard-Duty
No. of Stages Two Stage
Pressure [Max] 5000 psi
Spool Indicator Switch Code None
Seal Material Buna-N
Port Restrictor Plugs None
Pressure Port Check Valve Code None
Center Position P Blocked, A & B to T
Manual Override Plain Override
Pilot/Drain External Pilot/Internal Drain
Overrides Plain Override Solenoid Ends
Body Material Ductile Iron
Compatible Fluids Petroleum Oil
EN Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Crossover P Blocked, A or B to T
Electrical Connection No Connector
Tank Port Rating 5000
Voltage & Frequency 110/120 VAC - 50/60 Hz
Electrical Options None
Coil Rating Code B
Indicator Lights No
Pilot Pressure Code None
Reducer Module No
Actuation Identification Solenoid A, Solenoid B
Response Type Standard Response
Manual Override Option Code None
Surge Suppressor/Damper Code None
Rated Flow [Max] 175 gal/min
Design No. 10
Temperature Range [Max] 230 °F
Gauge Port SAE-4
Pilot Valve Type Code S
Mechanical Options None
Actuator Type Solenoid
Mechanical Options Code None
Electrical Connector Code None
Response Type Code None
Weight 35.0 LB