Vickers by Danfoss02-329180

02-329180

Vickers D08 Solenoid Valve
Item #102084135
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329180
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Operation Pilot Operated
Gauge Port SAE-4
Actuator Type Solenoid
Function 3-Position Spring Centered
Solenoid Double
Pressure Port Check Valve Code None
Spool Code 6
Solenoid Indicator Lights Code None
Housing Code W
Tank Port Rating 5000
Center Position P Blocked, A & B to T
Rated Flow [Max] 175 gal/min
Mounting Subplate/Manifold Mount
Surge Suppressor/Damper Code None
Pressure [Max] 5000 psi
Body Material Ductile Iron
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Temperature Range [Max] 230 °F
Response Type Standard Response
AC/DC AC
Compatible Fluids Petroleum Oil
Seal Material Buna-N
Pilot Pressure Code None
Solenoid Energization Code None
Spool Control Modification Code None
NFPA Size D08
Gauge Ports Code None
Pressure Port Check Valve Pressure N/A
Valve Type Standard-Duty
Overrides Plain Override Solenoid Ends
Port Restrictor Plugs None
Surge Suppressor/Damper None
Temperature Range [Min] -40 °F
Mechanical Options Code None
Actuation Identification Solenoid A, Solenoid B
Coil Type Code F
Spool Spring Arrangement Code C
Reducer Module No
Electrical Options Code None
Performance Standard Performance
Pilot/Drain External Pilot/Internal Drain
Coil Rating Code B
Mechanical Options None
Pilot Drain Code T
Electrical Connector Code None
Reducer Module Code None
EN Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Fluid Cleanliness 19/17/14 micron
Spool Indicator Switch Code None
Manual Override Option Code None
Pilot Valve Type CETOP 3, Standard Performance
Port Restrictor Plug Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Port T Pressure Rating 5000 psi
Crossover P Blocked, A or B to T
Design No. 10
Response Type Code None
Manual Override Plain Override
Pilot Valve Type Code S
Leakage Standard Performance
Electrical Connection No Connector
Indicator Lights No
Electrical Options None
No. of Stages Two Stage
Model No. DG5V-8-S-6C-T-M-FW-B-10
Weight 35.0 LB