- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| NFPA Size | D08 |
| Mechanical Options Code | None |
| Port T Pressure Rating | 5000 psi |
| Manual Override | Plain Override |
| Solenoid Energization Code | V |
| EN Code | None |
| Spool Indicator Switch Code | None |
| Seal Material | Buna-N |
| Port Restrictor Plugs | None |
| Leakage | Standard Performance |
| Solenoid Indicator Lights Code | L |
| Electrical Options | None |
| Mounting | Subplate/Manifold Mount |
| Pressure Port Check Valve Pressure | N/A |
| Fluid Cleanliness | 19/17/14 micron |
| Operation | Pilot Operated |
| AC/DC | AC |
| Reducer Module | No |
| Crossover | All Ports Open, Restricted |
| Pressure [Max] | 5000 psi |
| Electrical Connector Code | T |
| Spool Control Modification Code | 2 |
| Overrides | Plain Override Solenoid Ends |
| Body Material | Ductile Iron |
| Valve Type | Standard-Duty |
| Mechanical Options | Adjust Pilot Chokes on Both Ends |
| Gauge Ports Code | None |
| Surge Suppressor/Damper Code | None |
| Model No. | DG5V-8-S-8C-2-E-VM-FTWL-B-10 |
| Reducer Module Code | None |
| Pilot Pressure Code | E |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Temperature Range [Max] | 230 °F |
| Pressure Port Check Valve Code | None |
| Function | 3-Position Spring Centered |
| Temperature Range [Min] | -40 °F |
| Performance | Standard Performance |
| No. of Stages | Two Stage |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Port Restrictor Plug Code | None |
| Response Type Code | None |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Coil Rating Code | B |
| Solenoid | Double |
| Pilot Drain Code | None |
| Manual Override Option Code | None |
| Compatible Fluids | Petroleum Oil |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Actuator Type | Solenoid |
| Housing Code | W |
| Spool Spring Arrangement Code | C |
| Center Position | P to T, A & B Blocked |
| Surge Suppressor/Damper | None |
| Indicator Lights | Yes |
| Pilot/Drain | External Pilot/External Drain |
| Tank Port Rating | 5000 |
| Gauge Port | SAE-4 |
| Electrical Options Code | None |
| Spool Code | 8 |
| Response Type | Standard Response |
| Electrical Connection | Wired Terminal Block |
| Pilot Valve Type Code | S |
| Rated Flow [Max] | 175 gal/min |
| Actuation Identification | Solenoid A, Solenoid B |
| Design No. | 10 |
| Coil Type Code | F |
| Weight | 35.0 LB |