- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Solenoid Energization Code | V |
| Spool Code | 8 |
| Electrical Options Code | None |
| Port Restrictor Plugs | None |
| Reducer Module | No |
| Spool Spring Arrangement Code | C |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Operation | Pilot Operated |
| Pressure [Max] | 5000 psi |
| Gauge Port | SAE-4 |
| Rated Flow [Max] | 175 gal/min |
| Housing Code | W |
| Surge Suppressor/Damper | None |
| Center Position | P to T, A & B Blocked |
| Fluid Cleanliness | 19/17/14 micron |
| Overrides | Plain Override Solenoid Ends |
| Spool Indicator Switch Code | None |
| Electrical Connection | Wired Terminal Block |
| Coil Type Code | F |
| Port Restrictor Plug Code | None |
| Reducer Module Code | None |
| Seal Material | Buna-N |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| NFPA Size | D08 |
| Pilot Valve Type Code | S |
| Manual Override | Plain Override |
| Spool Control Modification Code | 2 |
| Compatible Fluids | Petroleum Oil |
| Mechanical Options Code | None |
| Mechanical Options | Adjust Pilot Chokes on Both Ends |
| Design No. | 10 |
| Temperature Range [Min] | -40 °F |
| Actuator Type | Solenoid |
| Electrical Options | None |
| Port T Pressure Rating | 5000 psi |
| Function | 3-Position Spring Centered |
| Pressure Port Check Valve Pressure | N/A |
| No. of Stages | Two Stage |
| Indicator Lights | Yes |
| Valve Type | Standard-Duty |
| Leakage | Standard Performance |
| Tank Port Rating | 5000 |
| AC/DC | AC |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Body Material | Ductile Iron |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Solenoid Indicator Lights Code | L |
| Pressure Port Check Valve Code | None |
| Model No. | DG5V-8-S-8C-2-E-VM-FTWL-B-10 |
| Mounting | Subplate/Manifold Mount |
| Surge Suppressor/Damper Code | None |
| Pilot/Drain | External Pilot/External Drain |
| Pilot Pressure Code | E |
| Crossover | All Ports Open, Restricted |
| Response Type Code | None |
| Manual Override Option Code | None |
| Solenoid | Double |
| Temperature Range [Max] | 230 °F |
| Pilot Drain Code | None |
| Actuation Identification | Solenoid A, Solenoid B |
| EN Code | None |
| Electrical Connector Code | T |
| Performance | Standard Performance |
| Coil Rating Code | B |
| Response Type | Standard Response |
| Gauge Ports Code | None |
| Weight | 35.0 LB |