- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Detented Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Solenoid | Double |
| Surge Suppressor/Damper | None |
| Operation | Pilot Operated |
| Electrical Connection | Wired Terminal Block |
| Overrides | Plain Override Solenoid Ends |
| Performance | Standard Performance |
| Seal Material | Buna-N |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Mounting | Subplate/Manifold Mount |
| Manual Override Option Code | None |
| Surge Suppressor/Damper Code | None |
| Reducer Module | No |
| EN Code | None |
| Crossover | P Blocked, A or B to T |
| Leakage | Standard Performance |
| Reducer Module Code | None |
| Electrical Connector Code | T |
| Spool Control Modification Code | 2 |
| Gauge Ports Code | None |
| Port T Pressure Rating | 5000 psi |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Function | 3-Position Detented |
| Pressure Port Check Valve Pressure | N/A |
| Pilot Pressure Code | None |
| Pilot/Drain | Internal Pilot/External Drain |
| Electrical Options Code | None |
| Temperature Range [Min] | -40 °F |
| Pressure [Max] | 5000 psi |
| Model No. | DG5V-8-S-6N-2-M-FTWL-B-10 |
| Temperature Range [Max] | 230 °F |
| Solenoid Energization Code | None |
| Body Material | Ductile Iron |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Compatible Fluids | Petroleum Oil |
| Manual Override | Plain Override |
| Port Restrictor Plugs | None |
| Design No. | 10 |
| Port Restrictor Plug Code | None |
| Spool Code | 6 |
| Coil Type Code | F |
| Actuator Type | Solenoid |
| Fluid Cleanliness | 19/17/14 micron |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Rated Flow [Max] | 175 gal/min |
| Tank Port Rating | 5000 |
| Spool Spring Arrangement Code | N |
| Spool Indicator Switch Code | None |
| Pilot Drain Code | None |
| Mechanical Options Code | None |
| AC/DC | AC |
| Electrical Options | None |
| Coil Rating Code | B |
| Housing Code | W |
| Center Position | P Blocked, A & B to T |
| Valve Type | Standard-Duty |
| Pilot Valve Type Code | S |
| Solenoid Indicator Lights Code | L |
| Response Type | Standard Response |
| No. of Stages | Two Stage |
| Pressure Port Check Valve Code | None |
| Actuation Identification | Solenoid A, Solenoid B |
| NFPA Size | D08 |
| Response Type Code | None |
| Indicator Lights | Yes |
| Gauge Port | SAE-4 |
| Mechanical Options | Adjust Pilot Chokes on Both Ends |
| Weight | 35.0 LB |