Vickers by Danfoss02-339929

02-339929

Vickers D08 Solenoid Valve
Item #101906808
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function
Vickers by Danfoss02-339929
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Tank Port Rating 5000
Pilot Pressure Code None
Reducer Module Code None
Port Restrictor Plug Code None
Coil Type Code F
Housing Code W
Port Restrictor Plugs None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Body Material Ductile Iron
Design No. 10
Seal Material Buna-N
Spool Code 2
Pilot/Drain Internal Pilot/External Drain
Temperature Range [Max] 230 °F
Surge Suppressor/Damper None
Gauge Port SAE-4
Actuator Type Solenoid
Leakage Standard Performance
Overrides Plain Override Solenoid Ends
Spool Indicator Switch Code None
Fluid Cleanliness 19/17/14 micron
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Pressure [Max] 5000 psi
Compatible Fluids Petroleum Oil
Mechanical Options Single Solenoid Reverse Assembly
Surge Suppressor/Damper Code None
Center Position All Ports Blocked
Gauge Ports Code None
Manual Override Option Code None
Pilot Valve Type CETOP 3, Standard Performance
AC/DC AC
Solenoid Energization Code None
Performance Standard Performance
Electrical Connection No Connector
Solenoid Indicator Lights Code None
Electrical Options Code None
Spool Control Modification Code None
Indicator Lights No
EN Code None
No. of Stages Two Stage
Model No. DG5V-8-S-2AL-M-FW-B-10
Solenoid Single
Response Type Standard Response
Crossover All Ports Blocked
Function 2-Position Spring Offset, Left Hand Build
Pressure Port Check Valve Pressure N/A
Pilot Valve Type Code S
Operation Pilot Operated
Coil Rating Code B
Electrical Options None
Electrical Connector Code None
Rated Flow [Max] 175 gal/min
Manual Override Plain Override
Spool Spring Arrangement Code A
Actuation Identification Solenoid A
Mounting Subplate/Manifold Mount
Reducer Module No
NFPA Size D08
Pilot Drain Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pressure Port Check Valve Code None
Response Type Code None
Mechanical Options Code L
Valve Type Standard-Duty
Temperature Range [Min] -40 °F
Port T Pressure Rating 5000 psi
Weight 35.0 LB