Vickers by Danfoss02-344016

02-344016

Vickers D08 Solenoid Valve
Item #102061832
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-344016
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Temperatures not to exceed 170 °F (77 °C)
Mechanical Options None
Electrical Options Code None
Actuator Type Solenoid
Indicator Lights Yes
Tank Port Rating 5000
Mechanical Options Code None
Spool Indicator Switch Code None
Function 3-Position Spring Centered
Electrical Connection Wired Terminal Block
Fluid Cleanliness 19/17/14 micron
Performance Standard Performance
Pressure Port Check Valve Code None
Reducer Module Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Body Material Ductile Iron
Port Restrictor Plug Code None
Compatible Fluids Petroleum Oil
Pilot Valve Type CETOP 3, Standard Performance
Center Position P & B Blocked, A to T
Model No. DG5V-8-S-3C-E-M-FTWL-B-10
Pressure [Max] 5000 psi
Port Restrictor Plugs None
No. of Stages Two Stage
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Gauge Port SAE-4
Coil Rating Code B
Response Type Code None
Manual Override Plain Override
Temperature Range [Max] 230 °F
EN Code None
Operation Pilot Operated
Rated Flow [Max] 175 gal/min
Pilot Drain Code None
Pilot Pressure Code E
Actuation Identification Solenoid A, Solenoid B
Electrical Connector Code T
Reducer Module No
Pilot Valve Type Code S
Solenoid Indicator Lights Code L
Design No. 10
Crossover All Ports Blocked, or P & B Blocked, A to T
Electrical Options None
Manual Override Option Code None
Pilot/Drain External Pilot/External Drain
Surge Suppressor/Damper None
Temperature Range [Min] -40 °F
Solenoid Energization Code None
Spool Spring Arrangement Code C
Spool Control Modification Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Housing Code W
Gauge Ports Code None
Port T Pressure Rating 5000 psi
Pressure Port Check Valve Pressure N/A
NFPA Size D08
Valve Type Standard-Duty
Spool Code 3
Coil Type Code F
Response Type Standard Response
Solenoid Double
AC/DC AC
Overrides Plain Override Solenoid Ends
Mounting Subplate/Manifold Mount
Seal Material Buna-N
Leakage Standard Performance
Surge Suppressor/Damper Code None
Weight 35.0 LB