Vickers by Danfoss02-344016

02-344016

Vickers D08 Solenoid Valve
Item #102061832
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-344016
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Temperatures not to exceed 170 °F (77 °C)
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
AC/DC AC
Surge Suppressor/Damper Code None
Gauge Ports Code None
Actuator Type Solenoid
Surge Suppressor/Damper None
EN Code None
Spool Code 3
Electrical Connector Code T
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Valve Type Standard-Duty
Pressure Port Check Valve Pressure N/A
Port T Pressure Rating 5000 psi
Function 3-Position Spring Centered
Electrical Options None
Pilot Pressure Code E
Performance Standard Performance
Electrical Options Code None
Operation Pilot Operated
Crossover All Ports Blocked, or P & B Blocked, A to T
NFPA Size D08
Indicator Lights Yes
Coil Rating Code B
Voltage & Frequency 110/120 VAC - 50/60 Hz
Mechanical Options Code None
Port Restrictor Plugs None
Solenoid Indicator Lights Code L
Housing Code W
Manual Override Option Code None
Pressure Port Check Valve Code None
Reducer Module Code None
Seal Material Buna-N
Rated Flow [Max] 175 gal/min
Actuation Identification Solenoid A, Solenoid B
Solenoid Energization Code None
Solenoid Double
Pilot Valve Type CETOP 3, Standard Performance
Pilot Drain Code None
Design No. 10
Response Type Standard Response
Mounting Subplate/Manifold Mount
Mechanical Options None
Spool Indicator Switch Code None
Overrides Plain Override Solenoid Ends
Center Position P & B Blocked, A to T
Temperature Range [Min] -40 °F
No. of Stages Two Stage
Fluid Cleanliness 19/17/14 micron
Port Restrictor Plug Code None
Body Material Ductile Iron
Tank Port Rating 5000
Pilot/Drain External Pilot/External Drain
Spool Control Modification Code None
Gauge Port SAE-4
Spool Spring Arrangement Code C
Temperature Range [Max] 230 °F
Coil Type Code F
Reducer Module No
Electrical Connection Wired Terminal Block
Pilot Valve Type Code S
Leakage Standard Performance
Model No. DG5V-8-S-3C-E-M-FTWL-B-10
Pressure [Max] 5000 psi
Response Type Code None
Compatible Fluids Petroleum Oil
Manual Override Plain Override
Weight 35.0 LB